Drag Chain Control Cable for Continuous Movement

AMPO drag chain control cable combines Class 6 fine-stranded copper conductors with PVC or PUR sheath options for moving equipment. Select an unscreened construction or a CY/CP screened version to match your circuit, chain layout and installation conditions. Rated voltage: 300/500 V.

Key Advantages

  • Designed for movement: the supplied sheets describe continuous-motion applications; PVC and CY versions expressly specify standard drag chains without tensile load.
  • Class 6 copper conductors: fine-stranded bare copper provides the flexible conductor construction shared across the range.
  • Screened options: CY and CP add tinned copper braid for applications with increased EMC requirements.

Description

The range covers four configurations: PVC unscreened, PVC CY screened, PUR unscreened and PUR CP screened. All four use Class 6 bare copper conductors and a 300/500 V rating, while insulation, inner sheath, temperature limits and bending radii differ. PVC and CY constructions list a flexed bend radius of 10D; PUR and CP list 7.5D. Confirm the cable diameter, movement conditions and required service life before selection. These minimum radii do not establish a cycle-life guarantee.

Key Features

  • PVC and PUR choice: PVC versions use grey PVC sheaths; PUR versions use grey polyurethane sheaths with TPE/PP insulation specified in their sheets. 
  • CY and CP screening: CY uses a PVC inner sheath and CP a PUR inner sheath beneath the overall tinned copper braid. Screening performance also depends on routing and termination. 
  • Halogen-free options: the PUR and CP sheets state halogen-free construction. Verify the required test evidence; this does not establish low-smoke or circuit-integrity performance. 
  • Core identification: black numbered cores are specified with a green/yellow conductor; confirm the protective-conductor arrangement for the selected core count. 

Product Applications

Typical selection areas are moving machinery connections and cable-carrier installations requiring repeated bending. PVC and CY sheets specify standard drag chains without tensile load. CP adds screening and explicitly includes indoor and outdoor use; exposure and operating conditions require item-specific review.

Technical Specifications

Powerchain CP Cable — Dimensions

No. of CoresNominal Cross-sectional Area
mm²
Nominal Overall Diameter
mm
Nominal Weight
kg/km
20.57.191
20.757.598
21865
21.59.1134
22.510.1198
30.57.4104
30.757.8120
318.581
31.59.7109
32.510.6284
40.57.8122
40.758.383
41996
41.510.3217
42.511.6321
4414.4448
4616.6612
41020.8984
41624.61318
50.58.2131
50.75994
519.6168
51.511148
52.512.4293
5415.7505
5618.2741
51022.71058
516271710
70.59.5172
70.7510.3125
7111.2240
71.512.7325
72.514.7418
7418.6678
7621.61028
71027.11530
71632.42087
120.511230
120.7512.1308
12113358.2
121.515416
122.517.5589
180.512.8321
180.7513.8420
18115.3418
181.517.6564
182.520.6885
250.7517445
25118.4641
251.521888

Powerchain CY Cable — Dimensions

No. of CoresNominal Cross-sectional Area
mm²
Nominal Overall Diameter
mm
Nominal Weight
kg/km
20.57.798
20.758.3115
218.6127
21.59.8165
22.511.2223
30.58107
30.758.9132
319.2146
31.510.3186
32.511.8253
3413.8366
3615.1465
40.59131
40.759.4151
4110173
41.511.2221
42.512.9311
4415.2451
4617.1596
50.59.8153
50.7510.3177
5110.7199
51.512256
52.514.1369
5417.2570
5618.7710
70.511.3201
70.7512234
7112.8277
71.514.3357
72.517.4538
120.513.2272
120.7514.3328
12115.1380
121.517.5528
122.520.4746
180.515.6379
180.7517.2483
18117.9549
181.520.3726
250.518.7539
250.7520.2652
25121.1744
251.524.31009

Powerchain PUR Cable — Dimensions

No. of CoresNominal Cross-sectional Area
mm²
Nominal Overall Diameter
mm
Nominal Weight
kg/km
20.5536
20.755.457
215.865
21.56.865
22.57.8115
30.55.257
30.755.773
316.184
31.57.2110
32.58.2143
40.55.756
40.756.395
416.8111
41.58134
42.58.9174
4411.6257
4613.6322
41017.6585
41621.21006
50.757.176
517.4138
51.58.7168
52.510198
5412.9337
5615.2509
51019.5817
51623.61172
70.57.479
70.758.3106
718.9182
71.510.5232
72.513.8266
7415.6479
7618.3693
71023.71054
71628.61709
120.59176
120.7510.1248
12110.7261
121.512.8305
122.514.6421
180.510.4186
180.7511.6252
18112.8390
181.515.2507
250.512.7196
250.7514.1351
25115.5445
251.518.2647

Powerchain Cable — Dimensions

No. of CoresNominal Cross-sectional Area
mm²
Nominal Overall Diameter
mm
Nominal Weight
kg/km
20.5644
20.756.452
216.760
21.57.680
22.59117
30.56.348
30.756.961
317.271
31.5894
32.59.7154
3411.9238
3613312
40.56.960
40.757.474
417.888
41.58.9118
42.510.6173
4413.1284
4614.4368
50.57.572
50.758.392
518.7109
51.510147
52.511.8216
5414.5352
5616498
70.59.1104
70.7510132
7110.5156
71.512210
72.514.5311
120.510.9148
120.7512190
12112.8233
121.514.6314
122.517.5468
180.513.1221
180.7514.3284
18115339
181.517.4466
250.515.8319
250.7517.3406
25118.2489
251.521670

Product Applications

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Class 6 fine-stranded bare copper conductors are insulated with PVC, PP or TPE and assembled into multiple cores. Screened versions include a PVC or PUR inner sheath and tinned copper braid, followed by a PVC or PUR outer sheath according to cable type.

Cable and conductor quality inspection and testing

Inspection

Inspection should verify conductor construction, insulation and sheath condition, dimensional parameters, electrical characteristics and the applicable catalogue requirements before release.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished control cables are supplied on suitable drums or coils according to cable size, length and shipment requirements. Product identification should distinguish the insulation system, conductor size, number of cores and production batch.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Shipment records should link the supplied cable lengths to the applicable packing list, technical documentation and inspection records to support warehouse handling and project traceability.

Frequently Asked Questions

Which configuration should I choose?

Select PVC or PUR against the installation requirements. Choose CY for a screened PVC construction or CP for a screened PUR construction. Confirm temperature, diameter and chain radius for the selected item.

The sheets list 10D flexed for PVC/CY and 7.5D for PUR/CP. For example, a 10 mm cable gives 100 mm at 10D or 75 mm at 7.5D. These are calculated examples; confirm the actual cable and duty.

No cycle count is provided. Submit travel, speed, acceleration, bending radius, duty cycle, temperature and required life so suitability and test evidence can be reviewed. Class 6 construction alone is not a life guarantee.

CP expressly lists indoor/outdoor use. Outdoor suitability for the other versions and torsion or robotic duty are not established by the supplied sheets. Specify UV, moisture, chemicals and twisting conditions before ordering.

Provide configuration, cores × mm², quantity, cut lengths, voltage, protective-conductor requirements and chain operating data. Include screening, environmental exposure and any halogen or flame-test documentation required.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
liyy-cable
LiYY Cable for Indoor Signal and Data Connections
sy-control-cable
SY Control Cable with Galvanised Steel Wire Braid
drag-chain-control-cable
Drag Chain Control Cable for Continuous Movement
Compatible Hardware
liyy-cable
LiYY Cable for Indoor Signal and Data Connections
sy-control-cable
SY Control Cable with Galvanised Steel Wire Braid
drag-chain-control-cable
Drag Chain Control Cable for Continuous Movement
Knowledge Articles
AAC vs AAAC vs ACSR: Which Overhead Conductor to Choose?
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines

For Immediate Assistance, Please Contact us Now!