Drag Chain Control Cable for Continuous Movement
AMPO drag chain control cable combines Class 6 fine-stranded copper conductors with PVC or PUR sheath options for moving equipment. Select an unscreened construction or a CY/CP screened version to match your circuit, chain layout and installation conditions. Rated voltage: 300/500 V.
Key Advantages
- Designed for movement: the supplied sheets describe continuous-motion applications; PVC and CY versions expressly specify standard drag chains without tensile load.
- Class 6 copper conductors: fine-stranded bare copper provides the flexible conductor construction shared across the range.
- Screened options: CY and CP add tinned copper braid for applications with increased EMC requirements.
Description
The range covers four configurations: PVC unscreened, PVC CY screened, PUR unscreened and PUR CP screened. All four use Class 6 bare copper conductors and a 300/500 V rating, while insulation, inner sheath, temperature limits and bending radii differ. PVC and CY constructions list a flexed bend radius of 10D; PUR and CP list 7.5D. Confirm the cable diameter, movement conditions and required service life before selection. These minimum radii do not establish a cycle-life guarantee.
Key Features
- PVC and PUR choice: PVC versions use grey PVC sheaths; PUR versions use grey polyurethane sheaths with TPE/PP insulation specified in their sheets.
- CY and CP screening: CY uses a PVC inner sheath and CP a PUR inner sheath beneath the overall tinned copper braid. Screening performance also depends on routing and termination.
- Halogen-free options: the PUR and CP sheets state halogen-free construction. Verify the required test evidence; this does not establish low-smoke or circuit-integrity performance.
- Core identification: black numbered cores are specified with a green/yellow conductor; confirm the protective-conductor arrangement for the selected core count.
Product Applications
Typical selection areas are moving machinery connections and cable-carrier installations requiring repeated bending. PVC and CY sheets specify standard drag chains without tensile load. CP adds screening and explicitly includes indoor and outdoor use; exposure and operating conditions require item-specific review.
Technical Specifications
Powerchain CP Cable — Dimensions
| No. of Cores | Nominal Cross-sectional Area mm² | Nominal Overall Diameter mm | Nominal Weight kg/km |
|---|---|---|---|
| 2 | 0.5 | 7.1 | 91 |
| 2 | 0.75 | 7.5 | 98 |
| 2 | 1 | 8 | 65 |
| 2 | 1.5 | 9.1 | 134 |
| 2 | 2.5 | 10.1 | 198 |
| 3 | 0.5 | 7.4 | 104 |
| 3 | 0.75 | 7.8 | 120 |
| 3 | 1 | 8.5 | 81 |
| 3 | 1.5 | 9.7 | 109 |
| 3 | 2.5 | 10.6 | 284 |
| 4 | 0.5 | 7.8 | 122 |
| 4 | 0.75 | 8.3 | 83 |
| 4 | 1 | 9 | 96 |
| 4 | 1.5 | 10.3 | 217 |
| 4 | 2.5 | 11.6 | 321 |
| 4 | 4 | 14.4 | 448 |
| 4 | 6 | 16.6 | 612 |
| 4 | 10 | 20.8 | 984 |
| 4 | 16 | 24.6 | 1318 |
| 5 | 0.5 | 8.2 | 131 |
| 5 | 0.75 | 9 | 94 |
| 5 | 1 | 9.6 | 168 |
| 5 | 1.5 | 11 | 148 |
| 5 | 2.5 | 12.4 | 293 |
| 5 | 4 | 15.7 | 505 |
| 5 | 6 | 18.2 | 741 |
| 5 | 10 | 22.7 | 1058 |
| 5 | 16 | 27 | 1710 |
| 7 | 0.5 | 9.5 | 172 |
| 7 | 0.75 | 10.3 | 125 |
| 7 | 1 | 11.2 | 240 |
| 7 | 1.5 | 12.7 | 325 |
| 7 | 2.5 | 14.7 | 418 |
| 7 | 4 | 18.6 | 678 |
| 7 | 6 | 21.6 | 1028 |
| 7 | 10 | 27.1 | 1530 |
| 7 | 16 | 32.4 | 2087 |
| 12 | 0.5 | 11 | 230 |
| 12 | 0.75 | 12.1 | 308 |
| 12 | 1 | 13 | 358.2 |
| 12 | 1.5 | 15 | 416 |
| 12 | 2.5 | 17.5 | 589 |
| 18 | 0.5 | 12.8 | 321 |
| 18 | 0.75 | 13.8 | 420 |
| 18 | 1 | 15.3 | 418 |
| 18 | 1.5 | 17.6 | 564 |
| 18 | 2.5 | 20.6 | 885 |
| 25 | 0.75 | 17 | 445 |
| 25 | 1 | 18.4 | 641 |
| 25 | 1.5 | 21 | 888 |
Powerchain CY Cable — Dimensions
| No. of Cores | Nominal Cross-sectional Area mm² | Nominal Overall Diameter mm | Nominal Weight kg/km |
|---|---|---|---|
| 2 | 0.5 | 7.7 | 98 |
| 2 | 0.75 | 8.3 | 115 |
| 2 | 1 | 8.6 | 127 |
| 2 | 1.5 | 9.8 | 165 |
| 2 | 2.5 | 11.2 | 223 |
| 3 | 0.5 | 8 | 107 |
| 3 | 0.75 | 8.9 | 132 |
| 3 | 1 | 9.2 | 146 |
| 3 | 1.5 | 10.3 | 186 |
| 3 | 2.5 | 11.8 | 253 |
| 3 | 4 | 13.8 | 366 |
| 3 | 6 | 15.1 | 465 |
| 4 | 0.5 | 9 | 131 |
| 4 | 0.75 | 9.4 | 151 |
| 4 | 1 | 10 | 173 |
| 4 | 1.5 | 11.2 | 221 |
| 4 | 2.5 | 12.9 | 311 |
| 4 | 4 | 15.2 | 451 |
| 4 | 6 | 17.1 | 596 |
| 5 | 0.5 | 9.8 | 153 |
| 5 | 0.75 | 10.3 | 177 |
| 5 | 1 | 10.7 | 199 |
| 5 | 1.5 | 12 | 256 |
| 5 | 2.5 | 14.1 | 369 |
| 5 | 4 | 17.2 | 570 |
| 5 | 6 | 18.7 | 710 |
| 7 | 0.5 | 11.3 | 201 |
| 7 | 0.75 | 12 | 234 |
| 7 | 1 | 12.8 | 277 |
| 7 | 1.5 | 14.3 | 357 |
| 7 | 2.5 | 17.4 | 538 |
| 12 | 0.5 | 13.2 | 272 |
| 12 | 0.75 | 14.3 | 328 |
| 12 | 1 | 15.1 | 380 |
| 12 | 1.5 | 17.5 | 528 |
| 12 | 2.5 | 20.4 | 746 |
| 18 | 0.5 | 15.6 | 379 |
| 18 | 0.75 | 17.2 | 483 |
| 18 | 1 | 17.9 | 549 |
| 18 | 1.5 | 20.3 | 726 |
| 25 | 0.5 | 18.7 | 539 |
| 25 | 0.75 | 20.2 | 652 |
| 25 | 1 | 21.1 | 744 |
| 25 | 1.5 | 24.3 | 1009 |
Powerchain PUR Cable — Dimensions
| No. of Cores | Nominal Cross-sectional Area mm² | Nominal Overall Diameter mm | Nominal Weight kg/km |
|---|---|---|---|
| 2 | 0.5 | 5 | 36 |
| 2 | 0.75 | 5.4 | 57 |
| 2 | 1 | 5.8 | 65 |
| 2 | 1.5 | 6.8 | 65 |
| 2 | 2.5 | 7.8 | 115 |
| 3 | 0.5 | 5.2 | 57 |
| 3 | 0.75 | 5.7 | 73 |
| 3 | 1 | 6.1 | 84 |
| 3 | 1.5 | 7.2 | 110 |
| 3 | 2.5 | 8.2 | 143 |
| 4 | 0.5 | 5.7 | 56 |
| 4 | 0.75 | 6.3 | 95 |
| 4 | 1 | 6.8 | 111 |
| 4 | 1.5 | 8 | 134 |
| 4 | 2.5 | 8.9 | 174 |
| 4 | 4 | 11.6 | 257 |
| 4 | 6 | 13.6 | 322 |
| 4 | 10 | 17.6 | 585 |
| 4 | 16 | 21.2 | 1006 |
| 5 | 0.75 | 7.1 | 76 |
| 5 | 1 | 7.4 | 138 |
| 5 | 1.5 | 8.7 | 168 |
| 5 | 2.5 | 10 | 198 |
| 5 | 4 | 12.9 | 337 |
| 5 | 6 | 15.2 | 509 |
| 5 | 10 | 19.5 | 817 |
| 5 | 16 | 23.6 | 1172 |
| 7 | 0.5 | 7.4 | 79 |
| 7 | 0.75 | 8.3 | 106 |
| 7 | 1 | 8.9 | 182 |
| 7 | 1.5 | 10.5 | 232 |
| 7 | 2.5 | 13.8 | 266 |
| 7 | 4 | 15.6 | 479 |
| 7 | 6 | 18.3 | 693 |
| 7 | 10 | 23.7 | 1054 |
| 7 | 16 | 28.6 | 1709 |
| 12 | 0.5 | 9 | 176 |
| 12 | 0.75 | 10.1 | 248 |
| 12 | 1 | 10.7 | 261 |
| 12 | 1.5 | 12.8 | 305 |
| 12 | 2.5 | 14.6 | 421 |
| 18 | 0.5 | 10.4 | 186 |
| 18 | 0.75 | 11.6 | 252 |
| 18 | 1 | 12.8 | 390 |
| 18 | 1.5 | 15.2 | 507 |
| 25 | 0.5 | 12.7 | 196 |
| 25 | 0.75 | 14.1 | 351 |
| 25 | 1 | 15.5 | 445 |
| 25 | 1.5 | 18.2 | 647 |
Powerchain Cable — Dimensions
| No. of Cores | Nominal Cross-sectional Area mm² | Nominal Overall Diameter mm | Nominal Weight kg/km |
|---|---|---|---|
| 2 | 0.5 | 6 | 44 |
| 2 | 0.75 | 6.4 | 52 |
| 2 | 1 | 6.7 | 60 |
| 2 | 1.5 | 7.6 | 80 |
| 2 | 2.5 | 9 | 117 |
| 3 | 0.5 | 6.3 | 48 |
| 3 | 0.75 | 6.9 | 61 |
| 3 | 1 | 7.2 | 71 |
| 3 | 1.5 | 8 | 94 |
| 3 | 2.5 | 9.7 | 154 |
| 3 | 4 | 11.9 | 238 |
| 3 | 6 | 13 | 312 |
| 4 | 0.5 | 6.9 | 60 |
| 4 | 0.75 | 7.4 | 74 |
| 4 | 1 | 7.8 | 88 |
| 4 | 1.5 | 8.9 | 118 |
| 4 | 2.5 | 10.6 | 173 |
| 4 | 4 | 13.1 | 284 |
| 4 | 6 | 14.4 | 368 |
| 5 | 0.5 | 7.5 | 72 |
| 5 | 0.75 | 8.3 | 92 |
| 5 | 1 | 8.7 | 109 |
| 5 | 1.5 | 10 | 147 |
| 5 | 2.5 | 11.8 | 216 |
| 5 | 4 | 14.5 | 352 |
| 5 | 6 | 16 | 498 |
| 7 | 0.5 | 9.1 | 104 |
| 7 | 0.75 | 10 | 132 |
| 7 | 1 | 10.5 | 156 |
| 7 | 1.5 | 12 | 210 |
| 7 | 2.5 | 14.5 | 311 |
| 12 | 0.5 | 10.9 | 148 |
| 12 | 0.75 | 12 | 190 |
| 12 | 1 | 12.8 | 233 |
| 12 | 1.5 | 14.6 | 314 |
| 12 | 2.5 | 17.5 | 468 |
| 18 | 0.5 | 13.1 | 221 |
| 18 | 0.75 | 14.3 | 284 |
| 18 | 1 | 15 | 339 |
| 18 | 1.5 | 17.4 | 466 |
| 25 | 0.5 | 15.8 | 319 |
| 25 | 0.75 | 17.3 | 406 |
| 25 | 1 | 18.2 | 489 |
| 25 | 1.5 | 21 | 670 |
Product Applications
Request the Complete Data Sheet
From Production to Delivery
From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.
Production
Class 6 fine-stranded bare copper conductors are insulated with PVC, PP or TPE and assembled into multiple cores. Screened versions include a PVC or PUR inner sheath and tinned copper braid, followed by a PVC or PUR outer sheath according to cable type.
Inspection
Inspection should verify conductor construction, insulation and sheath condition, dimensional parameters, electrical characteristics and the applicable catalogue requirements before release.
Packaging
Finished control cables are supplied on suitable drums or coils according to cable size, length and shipment requirements. Product identification should distinguish the insulation system, conductor size, number of cores and production batch.
Shipping
Shipment records should link the supplied cable lengths to the applicable packing list, technical documentation and inspection records to support warehouse handling and project traceability.
Frequently Asked Questions
Which configuration should I choose?
Select PVC or PUR against the installation requirements. Choose CY for a screened PVC construction or CP for a screened PUR construction. Confirm temperature, diameter and chain radius for the selected item.
What bend radius does my chain need?
The sheets list 10D flexed for PVC/CY and 7.5D for PUR/CP. For example, a 10 mm cable gives 100 mm at 10D or 75 mm at 7.5D. These are calculated examples; confirm the actual cable and duty.
How many bending cycles are guaranteed?
No cycle count is provided. Submit travel, speed, acceleration, bending radius, duty cycle, temperature and required life so suitability and test evidence can be reviewed. Class 6 construction alone is not a life guarantee.
Can it be used outdoors or in torsional movement?
CP expressly lists indoor/outdoor use. Outdoor suitability for the other versions and torsion or robotic duty are not established by the supplied sheets. Specify UV, moisture, chemicals and twisting conditions before ordering.
What do I need for a quotation?
Provide configuration, cores × mm², quantity, cut lengths, voltage, protective-conductor requirements and chain operating data. Include screening, environmental exposure and any halogen or flame-test documentation required.
Request for Free Consultation
Contact Information
Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.