SY Control Cable with Galvanised Steel Wire Braid
AMPO SY control cable combines Class 5 flexible copper conductors, PVC insulation and bedding, and a galvanised steel wire braid beneath a transparent PVC sheath. Rated 300/500 V, it is intended for industrial control and process-automation connections.
Key Advantages
- Steel braid reinforcement: galvanised steel wire braid provides an additional layer of mechanical protection.
- Transparent outer sheath: the clear PVC covering leaves the braided construction visible.
- Flexible copper conductors: Class 5 construction supports routing and connection within machinery.
Description
SY is a multicore PVC control cable with PVC bedding and an overall galvanised steel wire braid (GSWB). The supplied specification states a minimum braid coverage of 50% and a transparent Type TM2 PVC outer sheath. The construction table lists selected 3-, 4-, 5- and 7-core configurations, with conductor cross-sections from 1 to 16 mm² depending on core count. Confirm the required combination, diameter and identification before ordering.
Key Features
- GSWB construction: the steel braid surrounds the bedded core assembly. Its mechanical role does not establish a specified impact, crush or steel-wire-armour rating.
- PVC insulation and bedding: insulated copper cores sit within PVC bedding beneath the braid; Type TM2 PVC forms the transparent outer covering.
- Defined installation parameters: 300/500 V rating, a stated −15 to +70 °C range and a minimum bending radius of 10 times overall diameter. Confirm the applicable movement conditions.
- Colour identification: the sheet specifies coloured conductors and green/yellow inclusion in its 3-, 4- and 5-core identification schedules. Confirm the selected item, especially 7-core versions.
Product Applications
Typical applications include conveyor controls, instruments, assembly lines, production lines and similar process-automation equipment. Air-conditioning control connections are also listed. Select the cable against the circuit, route and mechanical conditions of the equipment.
Technical Specifications
SY PVC/PVC/GSWB/PVC Control Cable — Construction Parameters
| No. of Cores | Nominal Cross-sectional Area mm² | Nominal No. and Size of Wires No./mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
|---|---|---|---|---|
| 3 | 1 | 32/0.20 | 9 | 142 |
| 3 | 1.5 | 30/0.25 | 10.2 | 186 |
| 3 | 2.5 | 50/0.25 | 11.9 | 246 |
| 3 | 4 | 56/0.30 | 15.1 | 330 |
| 3 | 6 | 84/0.30 | 16.2 | 407 |
| 3 | 10 | 80/0.40 | 20.1 | 621 |
| 3 | 16 | 126/0.40 | 23.8 | 857 |
| 4 | 1 | 32/0.20 | 9.8 | 165 |
| 4 | 1.5 | 30/0.25 | 10.9 | 212 |
| 4 | 2.5 | 50/0.25 | 13.4 | 315 |
| 4 | 4 | 56/0.30 | 16.4 | 457 |
| 4 | 6 | 84/0.30 | 19.5 | 687 |
| 4 | 10 | 80/0.40 | 24.2 | 1009 |
| 4 | 16 | 126/0.40 | 27.1 | 1384 |
| 5 | 1 | 32/0.20 | 10.5 | 197 |
| 5 | 1.5 | 30/0.25 | 11.7 | 241 |
| 5 | 2.5 | 50/0.25 | 14.5 | 365 |
| 5 | 4 | 56/0.30 | 17.7 | 545 |
| 5 | 6 | 84/0.30 | 21.1 | 798 |
| 5 | 10 | 80/0.40 | 26.2 | 1197 |
| 5 | 16 | 126/0.40 | 30.6 | 1740 |
| 7 | 1 | 32/0.20 | 11.2 | 231 |
| 7 | 1.5 | 30/0.25 | 13.1 | 310 |
| 7 | 2.5 | 50/0.25 | 15.5 | 458 |
Product Applications
Request the Complete Data Sheet
From Production to Delivery
From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.
Production
Class 5 flexible copper conductors are PVC insulated and assembled into multiple cores, followed by PVC bedding, galvanized steel wire braid, and a transparent Type TM2 PVC outer sheath.
Inspection
Inspection should verify conductor construction, insulation and sheath condition, dimensional parameters, electrical characteristics and the applicable catalogue requirements before release.
Packaging
Finished control cables are supplied on suitable drums or coils according to cable size, length and shipment requirements. Product identification should distinguish the insulation system, conductor size, number of cores and production batch.
Shipping
Shipment records should link the supplied cable lengths to the applicable packing list, technical documentation and inspection records to support warehouse handling and project traceability.
Frequently Asked Questions
How does SY differ from CY cable?
SY uses galvanised steel braid, commonly selected for additional mechanical protection. CY uses copper braid for screening. Do not assume identical EMC performance; request evidence for the selected cable and system.
Can the steel braid replace an earth conductor or armour?
The supplied sheet does not establish the braid as a protective conductor or as rated steel wire armour. Confirm the protective-conductor arrangement and termination design rather than relying on the braid alone.
Can SY cable be used outdoors or in drag chains?
The supplied information does not establish UV resistance, outdoor suitability or continuous-flex endurance. State exposure, travel, speed and bending conditions so suitability can be reviewed before ordering.
What bending radius should I allow?
The sheet states 10 times the overall diameter. For example, a 10 mm diameter cable gives a calculated 100 mm minimum radius. This example does not establish dynamic service life; confirm the actual item and installation condition.
What do I need for a quotation?
Provide cores × mm², quantity, cut lengths, circuit voltage, core identification, protective-conductor requirements and installation conditions. Include destination and any required tests or compliance documents.