LiYY Cable for Indoor Signal and Data Connections

AMPO LiYY cable is an unscreened multicore PVC cable for indoor signal, data and process-control connections under low mechanical and tensile stress. It combines Class 5 fine-stranded bare copper conductors with PVC insulation and a grey PVC sheath.

Key Advantages

  • Unscreened construction: a multicore wiring option where an overall metallic screen is not required.
  • Flexible copper conductors: Class 5 fine-stranded bare copper supports equipment routing and connection.
  • Defined installation limits: separate fixed and flexed temperature and bend-radius values support application review.

Description

LiYY cable is intended for indoor industrial and equipment wiring, including computer systems, measuring equipment and process-control devices. The supplied construction uses PVC for both core insulation and outer sheath, without a specified metallic screen. The table lists selected configurations from 2 to 24 cores, using 0.14, 0.25, 0.34, 0.5, 0.75 and 1 mm² conductors. Available combinations depend on core count; confirm the selected construction and dimensions before ordering.

Key Features

  • Fine-stranded copper: Class 5 bare copper provides a flexible conductor construction for equipment connections.
  • PVC insulation and sheath: individual core insulation and the grey outer covering are PVC. This sheet does not establish LSZH properties. 
  • Fixed and flexed parameters: the sheet states 5D fixed and 7.5D flexed minimum bending radii, with different temperature limits. D is overall cable diameter. 
  • Flame-retardant specification: the supplied sheet describes flame retardance and references IEC 60332-1. Confirm the specific test method and supporting report for the selected item.

Product Applications

Typical uses include signal and data connections in computer equipment, measuring instruments and process-control devices in offices, laboratories and production lines. Select LiYY where mechanical stress and tensile loading are low; check screening and circuit requirements before choosing an unscreened cable.

Technical Specifications

LiYY Cable 250/250V — Construction Parameters

No. of CoresNominal Cross-sectional Area
mm²
Nominal Overall Diameter
mm
Nominal Weight
kg/km
20.143.212
20.253.617
20.344.219
20.55.623
20.755.948
21661
30.143.417
30.253.821
30.344.519
30.55.931
30.75657
40.143.719
40.254.127
40.344.932
40.56.438
40.756.569
416.585
50.14422
50.254.532
50.345.638
50.5747
70.144.727
70.255.442
70.346.650
70.57.665
80.145.330
80.256.151
80.347.261
80.57.975
120.145.848
120.256.671
120.347.985
120.59.7121
120.7510.1179
140.146.154
180.146.772
210.147.577
210.512.6184
240.147.894
240.513.6221

Product Applications

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Class 5 fine-stranded bare copper conductors are PVC insulated, assembled into a multicore configuration, and finished with a grey PVC outer sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection should verify conductor construction, insulation and sheath condition, dimensional parameters, electrical characteristics and the applicable catalogue requirements before release.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished control cables are supplied on suitable drums or coils according to cable size, length and shipment requirements. Product identification should distinguish the insulation system, conductor size, number of cores and production batch.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Shipment records should link the supplied cable lengths to the applicable packing list, technical documentation and inspection records to support warehouse handling and project traceability.

Frequently Asked Questions

Is LiYY cable screened, and when should I choose a screened alternative?

This LiYY construction is unscreened. If the equipment or installation requires a metallic screen for interference control, specify a suitable screened cable and review routing and termination requirements.

The sheet describes signal and data use but gives no protocol, impedance, bandwidth or transmission-distance rating. Do not infer Ethernet, fieldbus or high-speed performance from the LiYY designation alone.

The sheet specifies indoor use under low mechanical and tensile stress. It does not establish outdoor resistance or continuous-motion endurance. The flexed temperature and bend radius alone are not a drag-chain life rating.

Use the stated 5D fixed or 7.5D flexed limit. A 6 mm diameter cable gives calculated radii of 30 mm and 45 mm respectively. These examples do not establish cycle life; confirm the actual diameter and duty.

Provide cores × mm², quantity, cut lengths, circuit voltage, signal requirements, core identification and installation conditions. Include destination and any required fire-test or compliance documents.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
liyy-cable
LiYY Cable for Indoor Signal and Data Connections
sy-control-cable
SY Control Cable with Galvanised Steel Wire Braid
drag-chain-control-cable
Drag Chain Control Cable for Continuous Movement
Compatible Hardware
liyy-cable
LiYY Cable for Indoor Signal and Data Connections
sy-control-cable
SY Control Cable with Galvanised Steel Wire Braid
drag-chain-control-cable
Drag Chain Control Cable for Continuous Movement
Knowledge Articles
AAC vs AAAC vs ACSR: Which Overhead Conductor to Choose?
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines

For Immediate Assistance, Please Contact us Now!