AS/NZS 5000.1 Armoured Control Cable 0.6/1kV

AS/NZS 5000.1 Armoured Control Cable is a 0.6/1kV multicore-plus-earth cable designed for fixed control circuits in commercial, industrial, mining and utility installations where dependable electrical performance and mechanical protection are required. The cable uses plain annealed copper conductors, PVC V-90 insulation, PVC bedding, galvanised steel wire armour and a PVC 5V-90 outer sheath. It is available in 1.5 mm² and 2.5 mm² conductor sizes with multicore constructions from 2C+E to 50C+E, and is suitable for unenclosed fixed installation, conduit, direct burial and underground ducts.

Product Overview

This armoured control cable is intended for fixed low-voltage control and auxiliary circuits where the cable may be exposed to mechanical stress during installation or service. The multicore-plus-earth construction supports complex control systems with multiple circuits in a single cable, while the galvanised steel wire armour provides a protective layer around the laid-up insulated cores.

The product range is built around two copper conductor sizes. The 1.5 mm² series uses a 7/0.50 mm conductor construction and the 2.5 mm² series uses 7/0.67 mm. Both series use 0.8 mm nominal core insulation, with matching earth-conductor sections and progressively larger armour wire diameters as the cable size increases.

How the Construction Changes Across the Range

The cable construction is scaled according to conductor area and core count. Nominal core-insulation thickness remains 0.8 mm across the listed range, while earth-conductor insulation is 0.6 mm for the 1.5 mm² series and 0.7 mm for the 2.5 mm² series. As the number of cores increases, the diameter over bedding, armour wire diameter, overall cable diameter and cable mass also increase.

Armour wire diameter ranges from 0.90 mm to 1.60 mm in the 1.5 mm² series and from 0.90 mm to 2.00 mm in the 2.5 mm² series. This makes the armour specification an important part of cable selection, particularly for large multicore constructions.

Product Construction

Rated voltage

0.6/1kV

Conductor

Plain annealed copper

Conductor construction

1.5 mm²: 7/0.50 mm; 2.5 mm²: 7/0.67 mm

Insulation

PVC V-90

Core identification

White cores with black letter numbering; green/yellow earth

Bedding

PVC bedding, as shown in the supplied construction diagram

Armour

Galvanised steel wire armour

Outer sheath

PVC 5V-90

Standard sheath colour

Orange; other colours available on request

Catalogue core range

2C+E to 50C+E

Catalogue conductor sizes

1.5 mm² and 2.5 mm²

Typical Applications

  • Commercial and industrial control circuits.
  • Mining systems where additional mechanical protection may be required.
  • Electricity authority and utility control installations.
  • Unenclosed fixed installation where permitted by the project design.
  • Installation in conduit.
  • Direct burial.
  • Underground ducts.
  • Locations where risk of mechanical damage makes armouring desirable.

Technical Data

The following table reproduces the dimensional and mass data from the supplied catalogue. It is manufacturer/catalogue data for this cable range, not a reproduction of a standard table.

Area mm² Cores Conductor No./OD Insul. mm Earth area mm² Earth insul. mm Dia. over bedding mm Armour dia. mm Overall dia. mm Approx. mass kg/km
1.5 2C+E 7/0.50 0.8 1.5 0.6 9.0 0.90 14.5 405
1.5 3C+E 7/0.50 0.8 1.5 0.6 9.8 0.90 15.4 440
1.5 4C+E 7/0.50 0.8 1.5 0.6 10.7 0.90 16.3 550
1.5 6C+E 7/0.50 0.8 1.5 0.6 11.7 0.90 17.3 690
1.5 8C+E 7/0.50 0.8 1.5 0.6 13.6 1.25 19.9 770
1.5 10C+E 7/0.50 0.8 1.5 0.6 14.9 1.25 21.2 920
1.5 12C+E 7/0.50 0.8 1.5 0.6 16.2 1.25 22.5 1010
1.5 15C+E 7/0.50 0.8 1.5 0.6 17.1 1.60 23.4 1110
1.5 20C+E 7/0.50 0.8 1.5 0.6 19.0 1.60 26.0 1535
1.5 25C+E 7/0.50 0.8 1.5 0.6 21.7 1.60 28.7 1670
1.5 30C+E 7/0.50 0.8 1.5 0.6 23.5 1.60 30.4 1840
1.5 40C+E 7/0.50 0.8 1.5 0.6 26.4 1.60 34.8 2260
1.5 50C+E 7/0.50 0.8 1.5 0.6 28.9 1.60 36.1 2400
2.5 2C+E 7/0.67 0.8 2.5 0.7 10.0 0.90 15.6 210
2.5 3C+E 7/0.67 0.8 2.5 0.7 10.9 0.90 16.5 250
2.5 4C+E 7/0.67 0.8 2.5 0.7 12.0 0.90 17.6 285
2.5 6C+E 7/0.67 0.8 2.5 0.7 13.1 1.25 19.4 365
2.5 8C+E 7/0.67 0.8 2.5 0.7 15.3 1.25 23.0 455
2.5 10C+E 7/0.67 0.8 2.5 0.7 16.8 1.25 23.0 530
2.5 12C+E 7/0.67 0.8 2.5 0.7 18.3 1.60 25.2 605
2.5 15C+E 7/0.67 0.8 2.5 0.7 19.3 1.60 26.3 715
2.5 20C+E 7/0.67 0.8 2.5 0.7 21.5 1.60 28.5 950
2.5 25C+E 7/0.67 0.8 2.5 0.7 24.6 1.60 31.8 1095
2.5 30C+E 7/0.67 0.8 2.5 0.7 26.6 1.60 33.8 1200
2.5 40C+E 7/0.67 0.8 2.5 0.7 30.4 2.00 38.8 1565
2.5 50C+E 7/0.67 0.8 2.5 0.7 33.3 2.00 41.7 1925

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Plain annealed copper conductors are insulated with PVC V-90, assembled with the required earth conductor, bedded, armoured with galvanised steel wire and finished with a PVC 5V-90 outer sheath. Conductor size, core count, insulation thickness and armour diameter are produced according to the approved cable design.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, insulation and sheath condition, armour integrity, overall dimensions and electrical performance against the approved technical schedule. Key dimensional parameters such as insulation thickness, diameter over bedding, armour wire diameter and overall cable diameter are checked before release.

Packaged cable drums stored in the factory warehouse

Packaging

Finished armoured control cables are wound onto suitable cable drums according to ordered cable size and length. Cable ends are secured and protected, while drum identification can include cable type, conductor size, core configuration, length and project reference for shipment traceability.

Wooden cable drums secured inside a shipping container

Shipping

Before shipment, cable drums and accompanying technical documents are checked against the order and packing list. Delivery can be arranged for international project shipments with the required product identification, inspection records and technical documentation prepared according to customer and project requirements.

Frequently Asked Questions

What does AS/NZS 5000.1 cover?

Public catalogue descriptions state that AS/NZS 5000.1 covers construction, dimensions and tests for polymeric-insulated single- and multicore cables up to and including 0.6/1 (1.2) kV.

1.5 mm² and 2.5 mm².

2C+E through 50C+E.

Galvanised steel wire armour. The armour-wire diameter varies by cable size and core count.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
BS 7629-1 SR Insulated Fire Resistant Control Cable 300/500V
BS 7629-1 Fire Resistant Screened Control Cable 300/500V
BS 5839-9 Emergency Voice Communication Fire Resistant Screened Cable
Compatible Hardware
BS 7629-1 SR Insulated Fire Resistant Control Cable 300/500V
BS 7629-1 Fire Resistant Screened Control Cable 300/500V
BS 5839-9 Emergency Voice Communication Fire Resistant Screened Cable
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia