DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V

DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V is a flexible paired PVC signal and control cable with fine stranded copper conductors, DIN 47100 colour-coded cores, polyester wrapping, an overall tinned copper braid and a grey PVC outer sheath. It is intended for measuring, control, communication and data-processing circuits.

PRODUCT OVERVIEW

LiYCY TP provides a compact screened cable for low-voltage signal transmission. The twisted-pair layout supports control and measuring circuits, while the copper braid reduces electrical interference and can provide signal earthing and fixed-potential bonding where the installation design permits.

The catalogue product is rated 250V and is available from 0.14 mm2 to 1.00 mm2 in the listed pair counts. The published service range is -30 C to +70 C and the minimum bending radius is six times the finished cable diameter.

KEY FEATURES

  • DIN VDE 0814 design reference for the relevant product elements.
  • Fine stranded Class 5 bare copper conductors.
  • PVC Y12 core insulation and flexible PVC outer sheath.
  • Twisted-pair construction with DIN 47100 colour identification.
  • Overall tinned copper wire braid screen.
  • 250V nominal voltage and up to 1500V catalogue test voltage.
  • -30 C to +70 C catalogue temperature range.
  • Flame test reference IEC 60332-1-2 / VDE 0482-265-2-1.

CABLE CONSTRUCTION

Conductor

Fine stranded bare copper, Class 5 according to VDE 0295 / IEC 60228

Insulation

PVC Y12 according to DIN VDE 0207 Part 4

Core Assembly

Cores twisted into pairs; pairs laid up in layers

Core Identification

Colour coded according to DIN 47100

Wrapping

Polyester foil wrapping

Overall Screen

Tinned copper wire braid

Drain Wire

Tinned copper stranded drain wire when requested

Overall Jacket

Special flexible PVC compound

Sheath Colour

Grey RAL 7001 or pebble grey RAL 7032; other colours on request

DIN VDE 0814 DESIGN FOCUS

Focus

How It Relates to This Product

Flexible Cord Design

Fine-wire conductors and a flexible PVC-sheathed multi-pair construction

Paired Assembly

Cores twisted into pairs and pairs laid up in layers

Screening

Overall tinned copper wire braid for electromagnetic screening and equipotential bonding

Temperature Basis

Catalogue service range -30 C to +70 C

Core Colours

DIN 47100 colour identification

WHY DIN VDE 0814

DIN VDE 0814 is used on this page as the principal reference for the flexible cord and cable assembly. The LiYCY TP construction combines fine stranded conductors, paired PVC insulated cores, an overall tinned copper braid and a flexible PVC sheath. Published sizes, diameters and weights remain manufacturer product data.

DIN 47100 is retained as the conductor colour-identification reference and is not presented as the complete finished-cable manufacturing standard.

ELECTRICAL AND THERMAL PERFORMANCE

Condition

Catalogue Value

Nominal Voltage

250V

Test Voltage

26 AWG: 1200V; conductor sizes larger than 26 AWG: 1500V

Temperature Range

-30 C to +70 C

Minimum Bending Radius

6 x finished cable diameter

Nominal Inductance

0.65 mH/km

Mutual Capacitance

Conductor/conductor 120 nF/km; conductor/screen 160 nF/km

PRODUCT APPLICATIONS

  • Measurement and instrumentation circuits.
  • Low-voltage control and monitoring systems.
  • Communication, office and data-processing equipment.
  • Switchboards, scales and appliance engineering.
  • Indoor dry or damp installations with low mechanical stress.
  • Applications requiring an overall braid screen against electrical interference.

Physical and electrical data reproduced from the supplied product schedule. Units are retained as provided in the source.

Pairs OD in OD mm Weight lb/1000 ft Weight kg/km
2 0.406 10.3 95 142
3 0.409 10.4 116 173
4 0.445 11.3 142 212
5 0.465 11.8 179 266

Physical and electrical data reproduced from the supplied product schedule. Units are retained as provided in the source.

Pairs OD in OD mm Weight lb/1000 ft Weight kg/km
2 0.339 8.6 62 93
3 0.343 8.7 87 129
4 0.370 9.4 98 146
6 0.437 11.1 133 198
8 0.516 13.1 174 259
12 0.587 14.9 238 354
16 0.650 16.5 308 459

Physical and electrical data reproduced from the supplied product schedule. Units are retained as provided in the source.

Pairs OD in OD mm Weight lb/1000 ft Weight kg/km
2 0.276 7.0 36 54
3 0.280 7.1 44 66
4 0.299 7.6 54 81
6 0.335 8.5 77 115
8 0.406 10.3 87 130
10 0.433 11.0 106 158
12 0.445 11.3 128 190
16 0.492 12.5 160 238
25 0.634 16.1 231 344

Physical and electrical data reproduced from the supplied product schedule. Units are retained as provided in the source.

Pairs OD in OD mm Weight lb/1000 ft Weight kg/km
2 0.224 5.7 26 39
3 0.228 5.8 32 48
4 0.244 6.2 36 54
6 0.280 7.1 57 85
8 0.323 8.2 65 97
10 0.343 8.7 74 110
12 0.350 8.9 95 142
16 0.402 10.2 103 154
20 0.445 11.3 124 184
25 0.492 12.5 160 238
30 0.516 13.1 181 270

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Conductors are insulated, colour identified, twisted into pairs, laid up in layers, wrapped, braid screened and sheathed with the specified grey PVC compound.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, insulation continuity, pair identification, braid coverage, finished diameter, cable weight, voltage test and marking.

Overhead conductors packed on wooden drums for shipment

Packaging

Cable is wound on reels or drums suitable for the ordered size and length. Marking, packing, inspection records and requested standard or test documentation are checked against the order before shipment.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Cable is wound on reels or drums suitable for the ordered size and length. Marking, packing, inspection records and requested standard or test documentation are checked against the order before shipment.

Frequently Asked Questions

What does DIN VDE 0814 mean on this product page

It identifies DIN VDE 0814 as the principal design reference for this version of the LiYCY TP landing page. The exact compliance statement must match the offered cable documentation and any applicable approval certificate.

No. DIN 47100 is used here for core colour identification. The cable construction, electrical data and finished dimensions are defined by the product specification and the other referenced standards.

The product is intended for low-voltage signal, measuring, communication and control circuits. Suitability for a particular installation must be confirmed against the governing electrical rules and project specification.

Use the catalogue values for preliminary cable selection, tray or conduit planning, shipping estimates and termination design. Final production values may vary within normal manufacturing tolerances.

Provide pair count, conductor size, required length, sheath colour, installation environment, standard edition, cable marking, test documentation and any special braid, drain-wire, flame or packaging requirements.

We provide a wide range of cable materials and electrical products, including aluminum conductors, aluminum rods, aluminum wires, overhead conductors, medium and low voltage power cables, cable insulation materials, filling materials, shielding materials, and cable manufacturing consumables.We provide customized solutions according to different cable manufacturing requirements.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!