BS 5266-1 Emergency Lighting Fire Resistant Screened Control Cable

BS 5266-1 Emergency Lighting Fire Resistant Screened Control Cable is a 300/500V mica-and-silicone-rubber insulated, overall-screened LSZH cable intended for emergency-lighting circuits in premises. Its fire-resistant construction, overall screen and low-smoke zero-halogen sheath support control and supply circuits where continued operation during fire conditions is a key project requirement.

PRODUCT OVERVIEW

This 300/500V fire-resistant overall-screened control cable combines plain annealed copper conductors with a mica-glass fire-resistant tape and fire-resistant silicone-rubber insulation, an aluminum/polyester overall screen with tinned-copper drain wire, and a low-smoke zero-halogen outer sheath. The construction is designed to maintain circuit integrity during fire conditions while also providing an overall screen for control and signalling circuits.

For emergency-lighting installations, the cable combines circuit-integrity capability with screened multicore construction. The 2-, 3- and 4-core versions include an uninsulated tinned-copper circuit protective conductor of the same section and class as the insulated conductors, while cables above four cores use a 0.5 mm² tinned-copper drain wire.

KEY FEATURES

  • 300/500V fire-resistant screened control cable.
  • Plain annealed copper conductors: solid Class 1 or stranded Class 2 to IEC/EN 60228.
  • Mica-glass fire-resistant tape with fire-resistant silicone-rubber insulation type EI2.
  • Aluminum/polyester overall screen with tinned-copper drain wire.
  • Thermoplastic LSZH outer sheath type LTS3; thermosetting LSZH SW2-SW4 can be offered.
  • PH120 mechanical-shock circuit-integrity reference in the product designation.
  • Operating temperature: -30°C to +90°C; installation temperature: -20°C to +50°C.
  • Minimum bending radius: 7.5 × overall diameter.
  • Application reference: BS 5266-1 for emergency lighting of premises.
  • Fire-resistant screened construction for emergency-lighting circuits.

EMERGENCY LIGHTING FOCUS

Emergency-lighting circuits need cable systems that continue to operate during abnormal and fire conditions long enough to support safe evacuation and emergency response. This cable family combines mica-based fire protection, silicone-rubber insulation, LSZH sheathing and overall screening, with fire-performance references including circuit integrity, mechanical shock and water-spray conditions.

FIRE PERFORMANCE

Performance

Referenced Test / Standard

Circuit integrity

IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814 (FE180); BS 8434-2 (120 min); BS 5839-1 Clause 26 2e; CEI 20-36/2-1; SS229-1; NBN C 30-004 (F3); NF C32-070-2.3 (CR1)

Circuit integrity with mechanical shock

EN 50200 (PH120); CEI 20-36/4-0

Circuit integrity with mechanical shock & water spray

EN 50200 Annex E

System circuit integrity

DIN 4102-12, E30 depending on lay system

Flame retardance – single vertical wire

EN/IEC/BS EN 60332-1-2 and listed equivalents

Reduced fire propagation – bundled cables

EN/IEC/BS EN 60332-3-24 (Cat. C) and listed equivalents

Halogen free

IEC 60754-1 and listed equivalents

No corrosive gas emission

IEC 60754-2 and listed equivalents

Minimum smoke emission

IEC 61034-1&2 and listed equivalents

No toxic gases

NES 02-713; NF C 20-454

CABLE CONSTRUCTION

Voltage Rating

300/500V

Conductors

Plain annealed copper; solid IEC/EN 60228 Class 1 or stranded Class 2

Insulation

Mica glass fire-resistant tape + fire-resistant silicone rubber compound type EI2

Cabling

Cores cabled in concentric layers with suitable non-hygroscopic fillers

Overall Screen

Aluminum/polyester tape with tinned copper drain wire

Circuit Protective Conductor

Uninsulated tinned copper conductor, same section and class as insulated conductors in 2-, 3- and 4-core cables

Drain Wire for >4 Cores

0.5 mm² tinned copper conductor

Outer Sheath

Thermoplastic LSZH LTS3; optional thermosetting LSZH SW2-SW4

Sheath Colour

Red or white; other colours on request

Operating Temperature

-30°C to +90°C

Installation Temperature

-20°C to +50°C

Minimum Bending Radius

7.5 × overall diameter

PRODUCT APPLICATIONS

  • Emergency lighting of premises referenced by BS 5266-1.
  • Escape-route and emergency-exit lighting circuits.
  • Central battery and emergency-lighting control circuits where screened fire-resistant cable is specified.
  • Building services requiring LSZH fire-resistant screened multicore cable.

CONSTRUCTION PARAMETERS

Cores Cross Section mm² Insulation mm Sheath mm Overall Diameter mm Approx. Weight kg/km
2 1.0 0.6 0.9 7.9 85
2 1.5 0.7 0.9 8.8 105
2 2.5 0.8 1.0 10.2 150
2 1.5 0.7 0.9 9.2 110
2 2.5 0.8 1.0 10.3 155
2 4.0 0.8 1.1 12.2 220
3 1.0 0.6 0.9 8.4 105
3 1.5 0.7 0.9 9.3 130
3 2.5 0.8 1.0 10.8 190
3 1.5 0.7 0.9 9.4 135
3 2.5 0.8 1.0 10.9 190
3 4.0 0.8 1.1 13.0 280
4 1.0 0.6 1.0 9.3 125
4 1.5 0.7 1.0 10.3 165
4 2.5 0.8 1.1 12.0 240
4 1.5 0.7 1.0 10.5 170
4 2.5 0.8 1.1 12.1 250
4 4.0 0.8 1.2 14.4 350
7 1.0 0.6 1.0 10.5 175
7 1.5 0.7 1.1 12.1 230
12 1.0 0.6 1.1 14.5 300
12 1.5 0.7 1.2 16.0 380
19 1.0 0.6 1.2 17.5 470
19 1.5 0.7 1.3 17.5 470

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Plain annealed copper conductors are prepared as solid Class 1 or stranded Class 2 constructions, wrapped with mica-glass fire-resistant tape, insulated with fire-resistant silicone rubber, cabled with fillers, screened with aluminum/polyester tape and a tinned-copper drain wire, then finished with the specified LSZH sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on circuit-protective conductor / drain-wire arrangement, screen continuity, mica and silicone-rubber insulation, LSZH sheath integrity, dielectric test, insulation resistance and specified fire-performance documentation.

Packaged cable drums stored in the factory warehouse

Packaging

Finished cables are wound onto suitable drums according to ordered size and length. Cable ends are secured and protected, and drum identification can include cable code, core count, conductor size, length and project reference.

Wooden cable drums secured inside a shipping container

Shipping

Before shipment, cable drums and accompanying technical documents are checked against the order and packing list. Test records, product identification and project documentation can be prepared according to customer requirements

Frequently Asked Questions

What system application is this page focused on?

Emergency lighting of premises referenced by BS 5266-1.

300/500V.

Yes. Aluminum/polyester tape with a tinned-copper drain wire.

Thermoplastic LSZH LTS3; thermosetting LSZH SW2-SW4 can be offered.

The source lists IEC 60331-21, BS 6387 CWZ, EN 50200 PH120, BS 8434-2 and other fire-performance references.

From Production to Delivery

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
BS 7629-1 SR Insulated Fire Resistant Control Cable 300/500V
BS 7629-1 Fire Resistant Screened Control Cable 300/500V
BS 5839-9 Emergency Voice Communication Fire Resistant Screened Cable
Compatible Hardware
BS 7629-1 SR Insulated Fire Resistant Control Cable 300/500V
BS 7629-1 Fire Resistant Screened Control Cable 300/500V
BS 5839-9 Emergency Voice Communication Fire Resistant Screened Cable
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!