1.9/3.3kV PVC Insulated Armoured Power Cable to BS 6346

This power cable is designed for power and control circuits with a rated voltage of 1.9/3.3 kV. Manufactured with heavy galvanized steel wire armour in full compliance with BS 6346, it offers excellent protection and is well adapted to underground use in industrial applications and moist areas.
‌Key Advantages‌
Steel Wire Armour
PVC Insulation & Sheath
Moisture Resistant
Full BS 6346 Compliance

Construction

‌Conductor‌Solid Aluminum or Copper conductor, round stranded or shaped, Class 2 to BS 6460, IEC 60228.
‌Insulation‌PVC (Polyvinyl Chloride) type TI1
‌Colour Code‌1 Core: Brown3 Cores: Brown, Black, Grey
‌Filler (optional)‌PVC or Polypropylene yarn
‌Binder Tape (optional)‌Polyester (Mylar) tape
‌Inner Sheath / Bedding‌PVC (Polyvinyl Chloride)
‌Armour‌Single Core: AWA (Aluminum Wire Armour)Multi Core: SWA (Steel Wire or Tape Armour)
‌Outer Sheath‌PVC (Polyvinyl Chloride), type TM1

Technical Information

‌Voltage Rating‌1900/3300V
‌Temperature Rating‌-20°C to +60°C
‌Bending Radius‌Single core: 10 × overall diameter  Multicores: 8 × overall diameter
‌Flame Retardant‌IEC 60332 part 1, BS 4066 part 1

Parameters

IEC 6346

Select a standard below to view the corresponding technical data. Our conductors are manufactured and tested in full compliance with international specifications.

Nominal Cross-sectional Area Strand Type Nominal Insulation thickness Nominal Bedding thickness Nominal Alum Wire dia. Nominal Sheath thickness Approx. Overall Diameter Aprrox Weight
1x50 19/1.78 2.2 0.8 1.25 1.6 21.0 840
1x70 19/2.14 2.2 0.8 1.25 1.6 22.8 1070
1x95 19/2.52 2.2 1.0 1.6 1.7 26.0 1445
1x120 37/2.03 2.2 1.0 1.6 1.7 27.7 1715
1x150 37/2.25 2.2 1.0 1.6 1.8 29.4 2010
1x185 37/2.52 2.2 1.0 1.6 1.8 31.3 2380
1x240 61/2.25 2.2 1.0 1.6 1.9 34.1 2975
1x300 61/2.52 2.4 1.0 1.6 1.9 37.0 3615
1x400 61/2.85 2.6 1.2 2.0 2.1 42.0 4655
1x500 61/3.20 2.8 1.2 2.0 2.1 45.6 5725
1x630 61/3.65 2.8 1.2 2.0 2.2 49.7 7150
1x800 127/2.85 2.8 1.4 2.5 2.4 55.8 9160
1x1000 127/3.20 3.0 1.4 2.5 2.5 61.0 11400
Nominal Cross-Sectional Area Nominal Insulation Thickness Nominal Bedding Thickness Nominal Alum Wire Armor Dia. Nominal Sheath Thickness Approx. Overall Diameter Approx. Cable Weight
mm² mm mm mm mm mm kg/km
1×50 2.2 0.8 1.25 1.6 19.8 625
1×70 2.2 0.8 1.25 1.6 21.3 735
1×95 2.2 1.0 1.6 1.7 24.3 965
1×120 2.2 1.0 1.6 1.7 25.6 1090
1×150 2.2 1.0 1.6 1.8 27.1 1250
1×185 2.2 1.0 1.6 1.8 28.8 1415
1×240 2.2 1.0 1.6 1.9 31.2 1680
1×300 2.4 1.0 1.6 1.9 33.7 1935
Nominal Cross-Sectional Area Number / Wire Nominal Insulation Thickness Nominal Bedding Thickness Nominal Wire Armor Dia. Nominal Sheath Thickness Approx. Overall Diameter Approx. Cable Weight
mm² No./mm mm mm mm mm mm kg/km
3×16 7/1.70 2.2 1.0 1.6 1.8 30.3 1700
3×25 7/2.14 2.2 1.0 1.6 1.8 33.1 2085
3×35 19/1.53 2.2 1.0 1.6 1.9 35.8 2405
3×35* 19/1.53 2.2 1.0 1.6 1.9 32.1 2405
3×50* 19/1.78 2.2 1.2 2.0 2.0 35.6 3160
3×70* 19/2.14 2.2 1.2 2.0 2.1 38.9 3925
3×95* 19/2.52 2.2 1.2 2.0 2.2 42.3 4860
3×120* 37/2.03 2.2 1.4 2.5 2.3 46.6 6205
3×150* 37/2.25 2.2 1.4 2.5 2.4 49.4 7175
3×185* 37/2.52 2.2 1.4 2.5 2.5 52.8 8320
3×240* 61/2.25 2.2 1.6 2.5 2.6 57.8 10395
3×300* 61/2.52 2.4 1.6 2.5 2.8 63.2 12575
3×400* 61/2.85 2.6 1.6 2.5 3.0 69.6 15325
Nominal Cross-Sectional Area Nominal Insulation Thickness Nominal Bedding Thickness Nominal Armor Dia. Nominal Sheath Thickness Approx. Overall Diameter Approx. Cable Weight
mm² mm mm mm mm mm kg/km
3×16 2.2 1.0 1.6 1.8 28.9 1630
3×25 2.2 1.0 1.6 1.8 31.3 1880
3×35 2.2 1.0 1.6 1.9 33.7 2145
3×35* 2.2 1.0 1.6 1.9 30.6 2145
3×50* 2.2 1.2 2.0 2.0 33.9 2880
3×70* 2.2 1.2 2.0 2.1 36.9 3340
3×95* 2.2 1.2 2.0 2.2 40.0 3870
3×120* 2.2 1.4 2.5 2.3 44.0 4980
3×150* 2.2 1.4 2.5 2.4 46.5 5585
3×185* 2.2 1.4 2.5 2.5 49.6 6250
3×240* 2.2 1.6 2.5 2.6 54.2 7315
3×300* 2.4 1.6 2.5 2.8 59.2 8365
* Shaped conductor (Class 1)

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

Application

These cables are used for power and control circuits, they can offer excellent protection through the use of a heavy galvanized steel wire armour,so they are well adapted to underground use in industrial applications, in moist areas.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Stranded annealed copper conductors are insulated with XLPE, assembled into the required multicore configuration, optionally filled and bound with polyester tape, then covered with the specified black PVC sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, insulation condition, core identification, sheath integrity, overall diameter, conductor resistance and test-voltage requirements against the approved technical schedule.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on suitable drums according to ordered size, weight and length. Cable ends are protected and drum identification can include cable type, conductor size, core count, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable drums and technical documents are checked against the order. Inspection records, identification data and requested test documentation can be prepared for the customer.

faq

What is the difference between IEC 60502-1 and BS 5467 cables?

IEC 60502-1 is the international standard for low voltage PVC insulated power cables up to 1kV, while BS 5467 is the British standard for armoured cables. Both standards cover similar cable types for 0.6/1kV applications. Our cables are manufactured to meet IEC 60502-1 requirements and can also be supplied to comply with BS 5467 upon request. The key differences are in dimensional tolerances and specific marking requirements, but the electrical and mechanical performance are essentially equivalent for most installation purposes.

The choice depends on your project requirements:

  • Copper conductors offer higher conductivity, better mechanical strength, smaller diameter for equivalent current rating, superior corrosion resistance, and easier termination. Recommended for industrial applications, smaller cross-sections, and where reliability is critical.
  • Aluminum conductors provide significant cost savings (typically 30-40% material cost reduction), lighter weight for easier installation, and are commonly used for larger cross-sections in utility distribution and construction projects. Note that aluminum requires larger conductor sizes for equivalent ampacity and proper anti-oxidant treatment at terminations.

Steel wire armour (SWA) or steel tape armour (STA) is recommended in the following scenarios:

  • Direct burial in the ground without conduit protection
  • Areas with risk of mechanical damage (construction sites, heavy traffic areas)
  • Underground duct banks where pulling forces may be high
  • Outdoor installations exposed to potential impact or rodent damage
  • Industrial environments with heavy machinery and equipment

Unarmoured cables are suitable for indoor installation in cable trays, conduits, wall chases, and other protected locations where mechanical damage risk is minimal.

Standard burial depth recommendations for SWA armoured cables:

  • General areas (footpaths, grass verges): minimum 600mm (24 inches) below ground level
  • Under roads and driveways: minimum 900mm (36 inches) below ground level
  • Under agricultural land: minimum 1000mm (40 inches)

Cables should be laid on a bed of clean sand or sifted soil, covered with sand, then protected with cable protection tiles or warning tape before backfilling. Always verify local electrical codes and regulations as requirements may vary by region.

Yes, we offer extensive customization options to meet specific project requirements including:

  • Special core configurations (e.g., 3+1E, 3+2E, 4+1E, custom multi-core)
  • Custom outer sheath colors (red, blue, grey, etc. for identification)
  • Special print marking with customer logo, project name, or custom text
  • Low smoke zero halogen (LSZH) versions for special fire safety requirements
  • UV-stabilized formulations for extreme outdoor exposure
  • Oil-resistant and chemical-resistant sheath compounds
  • Custom length drums and packaging

Custom orders typically require MOQ and may have slightly longer lead times. Contact our sales team with your specific requirements for a quote.

Typical production lead times:

  • Standard specifications (common sizes): 7-15 working days after order confirmation
  • Custom specifications or special requirements: 15-25 working days
  • Large volume orders: production schedule confirmed at time of order

We also maintain inventory of fast-moving standard sizes for immediate shipment. Transit time depends on destination port and shipping method. We can ship by sea (most cost-effective for large orders), air (urgent shipments), or rail (for Central Asian destinations).

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!