ICEA S-73-532 THHN/THWN-2 Unscreened Control Cable 600V

ICEA S-73-532 referenced THHN/THWN-2 Unscreened Control Cable is a 600V multicore control cable using bare annealed copper conductors, PVC-FR / Nylon insulation and a black special-PVC outer sheath without an overall metallic screen. The product uses E2 core identification referenced to ICEA S-73-532 and is intended for industrial supervisory and control circuits.

PRODUCT OVERVIEW

This product is part of a control-cable system built around PVC-FR / Nylon insulated copper conductors assembled beneath an overall special-PVC sheath. The source product data identifies the core colours as E2 per ICEA S-73-532, making conductor identification one of the clearest standard-specific features for this product family.

The unscreened construction omits the aluminum tape and tinned-copper drain wire used in the screened version. It is therefore positioned for general control circuits where a dedicated overall electrostatic screen is not specified, while retaining the same 600V and 90°C product ratings shown in the source data.

KEY FEATURES

  • Reference standard: ICEA S-73-532 / ANSI/NEMA WC 57.
  • Current published edition: 2021.
  • 600V voltage rating and +90°C temperature rating shown in the product data.
  • Bare annealed copper conductors.
  • PVC-FR / Nylon insulated cores.
  • E2 core identification referenced to ICEA S-73-532.
  • Unscreened construction: no aluminum-tape screen and no drain wire.
  • Black special-PVC outer sheath.
  • 10, 12 and 14 AWG sizes.
  • 2-core flat and multicore constructions up to 50 cores.

CABLE CONSTRUCTION

Conductor

Bare annealed copper

Insulation

PVC-FR / Nylon (Polyvinyl Chloride – Flame Retardant / Nylon)

Metallic Screen

None

Drain Wire

None

Ripcord

Nylon

Outer Sheath

Special PVC (Polyvinyl Chloride)

Sheath Colour

Black

Core Identification

Color coded as E2 per ICEA S-73-532

SCREENED VS UNSCREENED THHN/THWN-2 CONTROL CABLE

Feature

Unscreened Type

Screened Type

Metallic Screen

None

Aluminum tape

Drain Wire

None

Tinned copper, 16 AWG, 7 strand

Main Selection Reason

General control circuits where an overall metallic screen is not required

Control circuits where electrostatic interference needs to be reduced

Construction

Simpler cable build

Additional screen and drain wire

Overall Diameter / Weight

Generally slightly smaller and lighter

Generally slightly larger and heavier

EMC / Interference Control

Depends on routing and system design; no overall metallic screen

Overall screen provides a dedicated electrostatic shielding layer

Choose the unscreened version when the project does not require an overall metallic screen and cable routing is compatible with an unscreened control-cable design. Where the specification explicitly calls for shielding, or control circuits are routed near significant sources of electrical interference, the screened construction should be reviewed instead.

ICEA S-73-532 / NEMA WC 57 DESIGN FOCUS

Focus

How It Relates to This Product

Multiconductor Control Cable

The product is offered from 2 conductors through high-core-count control constructions

Core Identification

Source data explicitly states E2 colour coding per ICEA S-73-532

Conductor / Insulation System

Bare annealed copper with PVC-FR / Nylon insulated conductors

Overall Covering

Black special-PVC outer sheath

Screening Choice

This page covers the unscreened version; a separate aluminum-tape screened version is available

Technical Data

Dimensions, weight and nominal ampacity are provided by AWG size and core count

E2 CORE IDENTIFICATION

The product data states that core identification is colour coded as E2 per ICEA S-73-532. This is a meaningful standard-specific feature because multicore control cables depend on consistent conductor identification during panel wiring, field termination, inspection and maintenance.

For project supply, the required core-colour sequence, conductor marking and any customer-specific identification requirement should be confirmed before production, especially on higher-core-count cables.

PRODUCT APPLICATIONS

  • Class 1, Division 2 hazardous-location applications as stated in the product data, including oil, gas and petrochemical environments.
  • Cable trays and wireways.
  • Duct and conduit installations.
  • Aerial installation when properly supported by a messenger.
  • Direct-burial applications as stated in the product data.
  • Wet or dry locations.
  • Outdoor cable-tray installations where a sunlight-resistant rating is required.
Cores AWG PVC Insul. mm Nylon mm Sheath mm Overall Dia. mm Weight kg/km Nominal Ampacity A
2 Flat 10 0.51 0.10 1.14 6.37x10.58 166 40
2 Flat 12 0.38 0.10 1.14 5.72x9.12 115 30.0
2 Flat 14 0.38 0.10 1.14 5.21x8.00 86 40
3 10 0.51 0.10 1.14 11.37 237 30.0
3 12 0.38 0.10 1.14 9.56 156 25.0
3 14 0.38 0.10 1.14 8.52 114 25.0
4 10 0.51 0.10 1.14 12.45 298 32/40
4 12 0.38 0.10 1.14 10.36 188 24.0/30.0
4 14 0.38 0.10 1.14 9.25 135 20.0/25.0
5 10 0.51 0.10 1.14 14.41 391 32
5 12 0.38 0.10 1.14 11.39 247 24.0
5 14 0.38 0.10 1.14 10.09 174 20.0
6 10 0.51 0.10 1.14 15.67 482 32
6 12 0.38 0.10 1.14 12.40 292 24.0
6 14 0.38 0.10 1.14 10.95 204 20.0
7 10 0.51 0.10 1.14 15.67 515 28
7 12 0.38 0.10 1.14 12.40 320 21.0
7 14 0.38 0.10 1.14 10.95 226 17.5
8 10 0.51 0.10 1.14 16.97 591 28
8 12 0.38 0.10 1.14 14.20 377 21.0
8 14 0.38 0.10 1.14 11.84 260 17.5
9 10 0.51 0.10 1.14 18.31 672 28
9 12 0.38 0.10 1.52 15.27 440 21.0
9 14 0.38 0.10 1.14 12.76 290 17.5
10 10 0.51 0.10 1.52 19.57 726 20
10 12 0.38 0.10 1.52 16.28 488 21.0
10 14 0.38 0.10 1.52 14.38 345 12.5
11 10 0.51 0.10 1.52 19.86 789 20
11 12 0.38 0.10 1.52 16.51 531 15.0
11 14 0.38 0.10 1.52 14.58 372 12.5
12 10 0.51 0.10 1.52 20.49 852 20
12 12 0.38 0.10 1.52 17.02 560 15.0
12 14 0.38 0.10 1.52 15.01 396 12.5
13 10 0.51 0.10 2.03 21.88 961 20
13 12 0.38 0.10 1.52 17.31 616 15.0
13 14 0.38 0.10 1.52 15.27 427 12.5
14 10 0.51 0.10 2.03 22.60 1094 20
14 12 0.38 0.10 1.52 17.88 659 15.0
14 14 0.38 0.10 1.52 15.76 457 12.5
15 10 0.51 0.10 2.03 23.18 1161 20
15 12 0.38 0.10 1.52 18.35 700 15.0
15 14 0.38 0.10 1.52 16.16 485 12.5
16 10 0.51 0.10 2.03 23.81 1183 20
16 12 0.38 0.10 1.52 18.86 729 15.0
16 14 0.38 0.10 1.52 16.59 510 12.5
19 10 0.51 0.10 2.03 25.07 1360 20
19 12 0.38 0.10 1.52 19.86 853 15.0
19 14 0.38 0.10 1.52 17.45 589 12.5
20 10 0.51 0.10 2.03 25.82 1420 20
20 12 0.38 0.10 1.52 20.47 866 15.0
20 14 0.38 0.10 1.52 17.97 620 12.5
25 10 0.51 0.10 2.03 28.97 1753 18
25 12 0.38 0.10 2.03 24.00 1158 13.5
25 14 0.38 0.10 1.52 20.12 771 11.3
30 10 0.51 0.10 2.03 30.98 2075 18
30 12 0.38 0.10 2.03 25.61 1362 13.5
30 14 0.38 0.10 2.03 22.51 949 11.3
37 10 0.51 0.10 2.03 33.45 2520 16
37 12 0.38 0.10 2.03 27.58 1647 12.0
37 14 0.38 0.10 2.03 24.21 1152 10.0
40 10 0.51 0.10 2.03 34.75 2714 16
40 12 0.38 0.10 2.03 28.62 1810 12.0
40 14 0.38 0.10 2.03 25.10 1240 10.0
45 10 0.51 0.10 2.03 36.85 3036 14
45 12 0.38 0.10 2.03 30.3 2021 10.5
45 14 0.38 0.10 2.03 26.54 1381 8.8
50 10 0.51 0.10 2.03 38.27 3353 14
50 12 0.38 0.10 2.03 31.44 2228 10.5
50 14 0.38 0.10 2.03 27.51 1446 8.8

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Annealed copper conductors are insulated with the specified PVC-FR / Nylon system, assembled into the required flat or multicore construction, fitted with the nylon ripcord and finished with the black special-PVC sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor condition, insulation and nylon-layer thickness, core identification, sheath integrity, finished dimensions, cable weight and electrical requirements defined for the approved construction.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on suitable reels or drums according to cable size, weight and ordered length. Product identification can include standard reference, AWG size, core count, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable identification, packing and requested technical documents are checked against the order. Project-specific inspection records or approval documents should be confirmed before production.

Frequently Asked Questions

When should I use the unscreened version rather than the screened version?

Use the unscreened version where the control circuit does not require an overall aluminum-tape screen and the installation design can manage interference without dedicated cable shielding. If the project specification requires an electrostatic screen or the circuit is sensitive to nearby electrical interference, select the screened version instead.

No. The uploaded product is presented as a control cable and includes a broad multicore range. ICEA S-73-532 also covers control, thermocouple-extension and instrumentation cable families, but that does not mean every construction serves all three functions identically. Selection should follow the actual circuit and project specification.

Confirm the required standard edition, core-identification scheme, AWG size, core count, installation environment and any required test documents. If the buyer requires specific certification or witnessed tests, those items should be stated before quotation and production.

Provide core count, AWG size, length, installation environment and whether the project requires screened or unscreened construction. Also state E2 or other core-identification requirements, cable marking, packing length, standard edition and any inspection or documentation requirements.

We provide a wide range of cable materials and electrical products, including aluminum conductors, aluminum rods, aluminum wires, overhead conductors, medium and low voltage power cables, cable insulation materials, filling materials, shielding materials, and cable manufacturing consumables.We provide customized solutions according to different cable manufacturing requirements.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!