UL 1277 XHHW-2 Unscreened Control Cable 600V

UL 1277 XHHW-2 Unscreened Control Cable is a 600V multicore industrial control/tray cable with bare annealed copper conductors, flame-retardant XLPE insulation and a black special-PVC outer sheath. This page focuses on the finished cable assembly and installation environments associated with tray/control cable service.

PRODUCT OVERVIEW

The cable combines XHHW-2 XLPE-insulated conductors with an overall special-PVC sheath in an unscreened multicore construction. The source product data lists trays, wireways, ducts, conduit, aerial use with messenger support, direct burial, wet or dry locations and outdoor cable trays where sunlight resistance is required.

For the UL 1277 landing page, the emphasis is not only the XLPE insulation on the individual conductors but the complete multicore cable as an installation product. The listed 600V / 90°C construction is available in 10 AWG and 12 AWG with scheduled core counts up to 50.

KEY FEATURES

  • UL 1277 referenced electrical power/control tray-cable construction.
  • 600V, +90°C product rating.
  • Bare annealed copper conductors.
  • Flame-retardant XLPE insulation.
  • Black special-PVC outer sheath.
  • Unscreened multicore construction.
  • 10 AWG and 12 AWG listed sizes.
  • Scheduled multicore range from 2 to 50 cores.
  • Product data lists tray, wireway, duct, conduit, direct-burial, wet/dry and outdoor applications.

CABLE CONSTRUCTION

Conductor

Bare annealed copper

Insulation

Flame-retardant XLPE (Cross-Linked Polyethylene)

Binder Tape

Present in the listed construction; material not stated in the source data

Ripcord

Nylon

Metallic Screen

None

Outer Sheath

Special PVC (Polyvinyl Chloride), black

Core Identification

Not specified in the source product data; confirm project requirement

UL 1277 INSTALLATION FOCUS

Focus

How It Relates to This Product

Complete Cable Assembly

Multicore XHHW-2 insulated conductors under an overall PVC sheath

Cable Tray / Raceway

Trays, wireways, ducts and conduit are listed in the product application

Outdoor Use

Outdoor tray use with sunlight-resistant rating is stated

Wet / Dry Locations

Both are stated in the source product data

Direct Burial

Listed in the product application; confirm the marking on the offered cable

Hazardous Locations

Class 1, Division 2 is stated in the source product data; complete installation approval must be reviewed separately

UL 1277 VS UL 44 - WHY BOTH STANDARDS APPEAR

Standard

Primary Role on This Product

UL 1277

Complete multicore tray/control cable and installation category

UL 44

XHHW-2 thermoset-insulated conductor / cable insulation system

The two standards are complementary rather than redundant. UL 44 explains the XHHW-2 thermoset-insulated conductor system, while UL 1277 is the more useful reference when the buyer is evaluating the finished tray/control cable and its installation category.

PRODUCT APPLICATIONS

  • Oil-industry control and auxiliary circuits.
  • Cable trays and wireways.
  • Duct and conduit installations.
  • Aerial installations when properly supported by a messenger.
  • Direct burial as stated in the source product data.
  • Wet or dry industrial locations.
  • Outdoor cable trays where a sunlight-resistant rating is required.
  • Class 1, Division 2 hazardous-location applications as stated in the source product data.

The following table reproduces the listed XHHW-2 unscreened product schedule for 10 AWG and 12 AWG multicore constructions.

Cores AWG Insulation mm Sheath mm Overall Dia. mm Weight kg/km Nominal Ampacity A
2 10 0.76 1.14 11.94 190 40.0
3 10 0.76 1.14 12.57 259 40.0
4 10 0.76 1.14 13.84 332 32/40
5 10 0.76 1.52 16.00 432 32.0
6 10 0.76 1.52 17.40 507 32.0
7 10 0.76 1.52 17.40 568 28.0
8 10 0.76 1.52 18.80 607 28.0
9 10 0.76 1.52 20.32 713 28.0
10 10 0.76 1.52 21.72 752 20.0
11 10 0.76 2.03 23.11 865 20.0
12 10 0.76 2.03 23.75 932 20.0
13 10 0.76 2.03 24.13 997 20.0
14 10 0.76 2.03 24.89 1064 20.0
15 10 0.76 2.03 25.65 1131 20.0
20 10 0.76 2.03 28.58 1463 20.0
25 10 0.76 2.03 32.00 1799 18.0
30 10 0.76 2.03 34.16 2124 18.0
35 10 0.76 2.03 36.32 2447 16.0
40 10 0.76 2.03 38.35 2770 16.0
45 10 0.76 2.03 40.77 3098 14.0
50 10 0.76 2.03 42.29 3417 14.0
2 12 0.76 1.14 10.67 140 30.0
3 12 0.76 1.14 11.30 188 30.0
4 12 0.76 1.14 12.32 238 24.0/30.0
5 12 0.76 1.14 13.59 289 24.0
6 12 0.76 1.52 15.49 366 24.0
7 12 0.76 1.52 15.49 406 21.0
8 12 0.76 1.52 16.76 432 21.0
9 12 0.76 1.52 18.03 507 21.0
10 12 0.76 1.52 19.18 530 15.0
11 12 0.76 1.52 19.56 573 15.0
12 12 0.76 1.52 20.19 619 15.0
13 12 0.76 1.52 20.57 662 15.0
14 12 0.76 1.52 21.21 708 15.0
15 12 0.76 1.52 21.84 753 15.0
19 12 0.76 1.52 24.26 975 15.0
20 12 0.76 1.52 25.27 1025 15.0
25 12 0.76 1.52 28.32 1260 13.5
30 12 0.76 1.52 30.23 1481 13.5
35 12 0.76 1.52 32.13 1700 12.0
37 12 0.76 1.52 32.13 1897 12.0
40 12 0.76 1.52 33.91 1918 12.0
45 12 0.76 1.52 35.81 2140 10.5
50 12 0.76 1.52 37.21 2354 10.5

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Bare annealed copper conductors are insulated with flame-retardant XLPE, assembled into the required multicore construction, provided with the listed binder/ripcord arrangement and finished with the black special-PVC outer sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor condition, XLPE insulation thickness, sheath thickness, overall diameter, cable weight, electrical performance and consistency with the approved product schedule.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on suitable reels or drums according to cable size, weight and ordered length. Product identification can include standard reference, AWG size, core count, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable identification, packing and requested technical documentation are checked against the order. Project-specific inspection or approval documents should be confirmed before production.

Frequently Asked Questions

Can this cable be installed in trays, conduit and direct burial?

Those applications are all listed in the source product data. For project approval, confirm the exact markings and listing on the offered cable, especially for direct burial, sunlight resistance and wet locations.

The source product data states Class 1, Division 2 use, but hazardous-location suitability also depends on the complete wiring method, fittings, seals and governing electrical code. The cable marking and installation design should be reviewed together.

Use the unscreened version where the project does not require an overall metallic screen. If nearby electrical interference is a concern or the specification explicitly requires shielding, a screened control-cable construction should be evaluated.

They are important for tray loading, conduit fill, drum sizing, pulling and panel-entry design. High-core-count constructions become significantly larger and heavier, so mechanical planning should be completed together with electrical selection.

Provide AWG size, number of cores, total length and installation method. Also state required UL marking/listing, direct-burial, sunlight-resistant, wet-location or hazardous-location requirements, reel length and technical documents.

We provide a wide range of cable materials and electrical products, including aluminum conductors, aluminum rods, aluminum wires, overhead conductors, medium and low voltage power cables, cable insulation materials, filling materials, shielding materials, and cable manufacturing consumables.We provide customized solutions according to different cable manufacturing requirements.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!