NA2XS(F)2Y 26/45 (52) kV High Voltage Cable to IEC 60840

This high voltage cable is intended for power distribution networks and for linking generation units, plant and process connections. Rated at 26/45 (52) kV, it is suited to laying in ground, outdoors, indoors, in water and in cable ducts for power stations, industry and distribution networks. An integrated water-blocking tape stops water from travelling along the cable core.
Key Advantages
Aluminium Conductor, Watertight Version Available
Semi-Conductive Conductor and Insulation Screens
Stranded Copper Screen plus Copper Tape
Full IEC 60840 Compliance

Construction

‌Conductor‌Aluminium conductor (optional watertightness – WTC)
‌Conductor Screen‌Semi-conductive screen extruded
‌Insulation‌XLPE (Cross-linked Polyethylene)
‌Insulation Screen‌Semi-conductive screen extruded
‌Wrapping‌Semi-conductive water swelling tape
‌Metallic Screen‌Copper wires and copper tape
‌Wrapping‌Semi-conductive water swelling tape
‌Tape‌Longitudinally applied aluminium tape coated with PE Copolymer
‌Sheath‌PE (Polyethylene); Optional – semi-conductive layer
‌Sheath Colour‌Black

Parameters

NO.
OF
CORES
NOMINAL
CROSS-SECTIONAL
AREA
mm²
NOMINAL DIAMETER
OF CONDUCTOR
mm
INSULATION
mm
METALLIC SCREEN NOMINAL OUTER
DIAMETER OF CABLE
mm
NOMINAL WEIGHT
kg/km
MAXIMUM PULLING
FORCE
mm
MINIMUM BENDING
RADIUS
m
Nominal
thickness
Nominal
diameter over
Nominal cross
section
mm²
Nominal
diameter over
mm
1 95RM 11.3 9 30.5 35 34.3 41 1640 3.3 1
1 120RM 12.5 9 31.7 35 35.5 42 1760 4.2 1.1
1 150RM 14.1 9 33.3 35 37.1 43 1880 5.3 1.1
1 185RM 15.8 9 35 35 38.8 45 2060 6.5 1.1
1 240RM 17.9 9 37.1 35 40.9 47 2300 8.4 1.2
1 300RM 20 9 39.2 35 43 49 2540 10.5 1.2
1 400RM 22.9 9 42.5 35 46.7 53 2990 14 1.3
1 500RM 25.7 9 45.3 35 49.5 56 3420 17.5 1.4
1 630RM 29.3 9 49.1 35 53.3 60 3980 22.1 1.5
1 800RM 33 9 52.8 35 57 64 4600 28 1.6
1 1000RM 38 9 58.2 35 62.8 71 5520 35 1.8
1 1200RM 42.5 9 62.7 50 67.3 75 6510 42 1.9
1 1200RMS 43 9 65.2 50 69.8 78 6790 42 2

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

Application

High Voltage cables for distribution networks; also for connection to generation units and plant and process connection. For installation in ground,in water outdoors, indoors and in cable ducts for power stations, industry and distribution networks. The water blocking tape avoids waterpropagation inside the cable.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Stranded annealed copper conductors are insulated with XLPE, assembled into the required multicore configuration, optionally filled and bound with polyester tape, then covered with the specified black PVC sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, insulation condition, core identification, sheath integrity, overall diameter, conductor resistance and test-voltage requirements against the approved technical schedule.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on suitable drums according to ordered size, weight and length. Cable ends are protected and drum identification can include cable type, conductor size, core count, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable drums and technical documents are checked against the order. Inspection records, identification data and requested test documentation can be prepared for the customer.

faq

What does the designation "NA2XS(F)2Y" mean?‌

Each letter in the type code describes a construction feature of the cable — the aluminium conductor (N), the XLPE insulation (2X), the semi-conductive water swelling tape wrapping (S), the copper wire and copper tape metallic screen with the longitudinal aluminium/PE-copolymer tape (F), and the PE outer sheath (2Y). This coding system allows the full cable design to be identified directly from the type designation.

The cable is designed with XLPE insulation, which provides a high continuous conductor operating temperature and excellent dielectric strength. It performs reliably under the thermal and electrical stresses typical of 26/45 (52) kV distribution and connection applications. Detailed temperature ratings under continuous, emergency and short-circuit conditions are available on request.

The cable is rated ‌Uo/U = 26/45 (52) kV‌, where:

‌Uo = 26 kV‌ — the rated power-frequency voltage between conductor and screen (earth);
‌U = 45 kV‌ — the rated power-frequency voltage between conductors;
‌Um = 52 kV‌ — the maximum system voltage for which the cable is designed.

The NA2XS(F)2Y cable is manufactured with the basic design to IEC 60840 — Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV). On request, production can also follow other national or customer-specified standards.

Yes, we offer extensive customization options to meet specific project requirements including:

  • Special core configurations (e.g., 3+1E, 3+2E, 4+1E, custom multi-core)
  • Custom outer sheath colors (red, blue, grey, etc. for identification)
  • Special print marking with customer logo, project name, or custom text
  • Low smoke zero halogen (LSZH) versions for special fire safety requirements
  • UV-stabilized formulations for extreme outdoor exposure
  • Oil-resistant and chemical-resistant sheath compounds
  • Custom length drums and packaging

Custom orders typically require MOQ and may have slightly longer lead times. Contact our sales team with your specific requirements for a quote.

Typical production lead times:

  • Standard specifications (common sizes): 7-15 working days after order confirmation
  • Custom specifications or special requirements: 15-25 working days
  • Large volume orders: production schedule confirmed at time of order

We also maintain inventory of fast-moving standard sizes for immediate shipment. Transit time depends on destination port and shipping method. We can ship by sea (most cost-effective for large orders), air (urgent shipments), or rail (for Central Asian destinations).

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!