UL 1277 XHHW/PVC Type TC Control Cable 600V

UL 1277 XHHW/PVC Type TC Control Cable is a compact, flame-retardant 600V multicore control cable with XHHW-2 copper conductors, FRXLPE insulation and a moisture- and sunlight-resistant PVC outer jacket. It is designed for industrial power and control circuits requiring Type TC tray-cable installation and durable PVC jacketing.

PRODUCT OVERVIEW

The cable uses stranded bare annealed copper conductors with flame-retardant, moisture-resistant FRXLPE insulation. A flame-retardant PVC jacket provides the overall covering and is also described as moisture- and sunlight-resistant; LSOH can be supplied on request.

Primary installation environments include cable trays, raceways and outdoor messenger-supported routes. The product data also lists direct burial, Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions with three or more conductors are stated as suitable for exposed runs (TC-ER), and the cable may be used in wet or dry locations up to 90°C.

KEY FEATURES

  • UL 1277 Type TC control / tray cable product basis.
  • 600V, 90°C wet-or-dry construction.
  • XHHW-2 stranded bare annealed copper conductors.
  • Flame-retardant and moisture-resistant FRXLPE insulation.
  • Flame-retardant, moisture- and sunlight-resistant PVC jacket.
  • LSOH jacket available upon request.
  • Direct burial and Class 1, Division 2 applications stated in the source.
  • TC-ER exposed-run construction stated for 3 or more conductors.
  • AWG 14, 12 and 10 parameter schedules.

CABLE CONSTRUCTION

Conductor

Stranded bare annealed copper, 7 strands

Conductor Sizes

AWG 14, AWG 12 and AWG 10

Conductor Type

XHHW-2

Insulation

Flame-retardant and moisture-resistant Cross-Linked Polyethylene (FRXLPE)

Outer Jacket

Flame-retardant, moisture- and sunlight-resistant PVC

Optional Jacket

LSOH available upon request

Jacket Colour

Upon request; black preferred

Voltage Rating

600V

Temperature

Wet or dry locations, not exceeding 90°C

Screen / Armour

None stated

STANDARD REFERENCE & COMPLIANCE

Item

Details

Referenced Standard

UL 1277 – Electrical Power and Control Tray Cables

Current Status

Active

Current Edition

Edition 6

Current Published Revision

May 29, 2025

Product Designation

XHHW/PVC Type TC Control Cable, 600V

Compliance Note

Confirm the required UL listing/marking and ratings such as TC-ER, direct burial, wet location, sunlight resistance and hazardous-location use on the offered cable documentation.

XHHW/PVC VS XHHW/CPE

Feature

XHHW/PVC

XHHW/CPE

Insulated Conductors

XHHW-2 FRXLPE

XHHW-2 FRXLPE

Standard Outer Jacket

Flame-retardant PVC

Flame-retardant CPE

Moisture Resistance

Yes, stated

Yes, stated

Sunlight Resistance

Yes, stated

Yes, stated

Optional Jacket

LSOH on request

PVC / LSOH on request

Selection Focus

PVC-jacketed Type TC construction

CPE-jacketed Type TC construction

The two product families share the same XHHW-2 / FRXLPE conductor concept, but the outer jacket material is different. They should therefore remain separate product pages because the jacket material, procurement specification, SEO intent and project approval basis can differ.

 

UL 1277 TYPE TC DESIGN FOCUS

UL 1277 Focus

How It Applies to This Cable

Complete Cable Assembly

Multicore XHHW-2 conductors under an overall PVC jacket

Cable Tray / Raceway Use

Primary installations include cable trays and raceways

Outdoor Installation

Outdoor messenger-supported use is stated

Direct Burial

Listed in the source product application

Wet / Dry Locations

Both are stated up to 90°C

Hazardous Locations

Class 1, Division 2 use is stated; complete installation requirements also apply

TC-ER

3 or more conductors are stated as listed for exposed runs

PRODUCT APPLICATIONS

  • Industrial power and control circuits where compact flame-retardant cable is required.
  • Cable trays and raceways.
  • Outdoor messenger-supported installations.
  • Direct-burial routes where the required cable marking is confirmed.
  • Wet or dry industrial locations up to 90°C.
  • Class 1, Division 2 hazardous-location projects as stated in the source.
  • TC-ER exposed-run applications for qualifying constructions with 3 or more conductors.

The following schedule reproduces the listed XHHW/PVC Type TC cable dimensions and approximate weights for AWG 14, AWG 12 and AWG 10 constructions.

AWG Cores Jacket in Jacket mm OD in OD mm Weight lb/kft Weight kg/km
14 2 0.045 1.14 0.349 8.86 63 94
14 3 0.045 1.14 0.370 9.40 87 129
14 4 0.045 1.14 0.403 10.24 106 157
14 5 0.045 1.14 0.440 11.18 125 186
14 6 0.045 1.14 0.479 12.17 146 218
14 7 0.045 1.14 0.479 12.17 164 245
14 8 0.060 1.52 0.549 13.94 201 299
14 9 0.060 1.52 0.588 14.94 223 332
14 10 0.060 1.52 0.638 16.21 247 367
14 12 0.060 1.52 0.659 16.74 285 424
14 15 0.060 1.52 0.730 18.54 347 517
14 19 0.060 1.52 0.768 19.51 424 630
14 20 0.060 1.52 0.808 20.52 446 664
14 25 0.080 2.03 0.938 23.83 582 866
14 30 0.080 2.03 0.991 25.17 680 1012
14 37 0.080 2.03 1.067 27.10 818 1217
12 2 0.045 1.14 0.384 9.75 85 127
12 3 0.045 1.14 0.408 10.36 115 172
12 4 0.045 1.14 0.445 11.30 147 219
12 5 0.045 1.14 0.487 12.37 171 255
12 6 0.060 1.52 0.562 14.27 217 323
12 7 0.060 1.52 0.562 14.27 244 363
12 8 0.060 1.52 0.607 15.42 275 410
12 9 0.060 1.52 0.651 16.54 307 457
12 10 0.060 1.52 0.709 18.01 340 506
12 12 0.060 1.52 0.732 18.59 396 589
12 15 0.060 1.52 0.813 20.65 484 721
12 19 0.080 2.03 0.896 22.76 628 934
12 20 0.080 2.03 0.942 23.93 661 984
12 25 0.080 2.03 1.043 26.49 811 1207
12 30 0.080 2.03 1.104 28.04 953 1418
12 37 0.080 2.03 1.190 30.23 1152 1714
10 2 0.045 1.14 0.431 10.95 116 172
10 3 0.045 1.14 0.459 11.66 161 239
10 4 0.045 1.14 0.502 12.75 205 306
10 5 0.060 1.52 0.581 14.76 260 387
10 6 0.060 1.52 0.632 16.05 306 455
10 7 0.060 1.52 0.632 16.05 346 514
10 8 0.060 1.52 0.685 17.40 392 583
10 9 0.060 1.52 0.736 18.69 437 651
10 10 0.060 1.52 0.803 20.40 485 721
10 12 0.080 2.03 0.870 22.10 599 892
10 15 0.080 2.03 0.964 24.49 733 1091
10 19 0.080 2.03 1.014 25.76 901 1340
10 20 0.080 2.03 1.066 27.08 949 1412
10 25 0.080 2.03 1.184 30.07 1168 1739
10 30 0.080 2.03 1.254 31.85 1379 2052
10 37 0.080 2.03 1.355 34.42 1674 2491

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Stranded bare annealed copper conductors are insulated with FRXLPE, assembled into the required multicore configuration and finished with the specified flame-retardant PVC jacket.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, insulation and jacket condition, finished dimensions, cable weight, cable marking and the technical documents required by the project.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on reels or drums according to cable size, weight and ordered length. Product identification can include AWG size, core count, standard reference, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable identification, packing and requested test / approval documents are checked against the order. Project-specific documentation requirements should be agreed before production.

Frequently Asked Questions

When should I choose the PVC-jacketed version instead of the CPE-jacketed version?

Both product families use XHHW-2 FRXLPE-insulated conductors, so the main difference is the outer jacket. Choose the PVC-jacketed version when the project specification calls for PVC or when the required approval package is based on that construction. If the specification calls for CPE, use the separate XHHW/CPE product instead.

Type TC identifies the tray-cable product category. TC-ER is relevant when qualifying cable is permitted to leave the tray for an exposed run under the applicable installation rules. The product data states that constructions with three or more conductors are listed for exposed runs, but the exact ordered construction should still be checked for TC-ER marking.

Those applications are stated in the product data, and the PVC jacket is described as moisture- and sunlight-resistant. For project approval, confirm the actual cable marking/listing for sunlight resistance, wet location and direct burial.

The product data lists Class 1, Division 2 hazardous locations. The complete installation also depends on fittings, seals, wiring method and the governing electrical code, so the cable should be reviewed as part of the whole hazardous-location design.

The source states that LSOH is available on request. Because changing the jacket can change flame, smoke and approval performance, the alternative construction should be technically reviewed and supported by the required test or certification evidence before it is offered as equivalent.

We provide a wide range of cable materials and electrical products, including aluminum conductors, aluminum rods, aluminum wires, overhead conductors, medium and low voltage power cables, cable insulation materials, filling materials, shielding materials, and cable manufacturing consumables.We provide customized solutions according to different cable manufacturing requirements.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!