UL 1277 CU THHN Type TC Control Cable 600V

UL 1277 CU THHN Control Cable is a 600V unshielded multicore Type TC substation/control cable with annealed Class B compressed stranded copper conductors, heat- and moisture-resistant PVC insulation, a clear nylon conductor jacket and a black PVC overall jacket. It is designed for tray, conduit, underground duct and direct-burial installations in wet or dry locations.

PRODUCT OVERVIEW

Predominantly used in utility substations, this cable may be installed indoors or outdoors in cable trays, conduit and underground ducts, or directly buried. The brochure specifies conductor operating temperatures up to 75°C in wet locations and 90°C in dry locations.

The finished cable is unshielded. Insulated and nylon-jacketed conductors are cabled with non-hygroscopic polyethylene fillers where needed to maintain a circular cross-section, wrapped with a Mylar binder and protected by a heat-, moisture- and sunlight-resistant black PVC jacket.

KEY FEATURES

  • UL 1277 Type TC finished cable construction, rated 600V.
  • Operating temperature: 75°C wet and 90°C dry.
  • 16–10 AWG annealed Class B copper, unilay compressed stranded.
  • Heat- and moisture-resistant PVC insulation with a clear nylon (polyamide) conductor jacket.
  • Unshielded construction: no overall metallic shield and no drain wire.
  • Heat-, moisture- and sunlight-resistant black PVC overall jacket.
  • Color coding per ICEA S-73-532, Method 1, Table E-2.
  • 16 AWG uses 26 strands; 14, 12 and 10 AWG use 7 strands.
  • 2 to 12 conductors across the listed product schedule.
  • Brochure references ASTM, ANSI/ICEA S-73-532, UL 83, UL 66, UL 1277, UL 1581, UL 1685 and RoHS.

STANDARD REFERENCE & COMPLIANCE

Item

Details

Principal Finished-Cable Standard

UL 1277

Cable Type

Type TC Substation / Control Cable

Rated Voltage

600V

Additional References in Brochure

ANSI/ICEA S-73-532; UL 83 Type THHN; UL 66 Type TFFN; UL 1581; UL 1685; applicable ASTM; RoHS

Product Position

Unshielded copper THHN control cable with black PVC overall jacket

Compliance Note

Confirm exact UL listing, cable marking, direct-burial, wet-location, sunlight-resistance and flame-test approvals on the offered product documents.

UL 1277 is the principal finished-cable standard for this Type TC product. UL 83 Type THHN and UL 66 Type TFFN are conductor/component references listed by the brochure; they do not replace UL 1277 as the governing standard for the completed multicore tray/control cable.

UL 1277 PRODUCT & INSTALLATION FOCUS

Focus

How It Relates to This Product

Complete Cable Assembly

UL 1277 Type TC multicore copper control cable under an overall PVC jacket

Tray / Raceway Use

Brochure lists cable trays, conduit and underground duct

Indoor / Outdoor Use

Both are stated in the supplied applications

Wet / Dry Locations

75°C wet and 90°C dry conductor operating limits

Direct Burial

Stated in the brochure; confirm product marking and approval documentation

Shielding

Unshielded; no metallic shield or drain wire

STANDARD ROLE: FINISHED CABLE VS COMPONENT REFERENCES

Reference

Primary Role

Relevance to This Product

UL 1277

Finished Type TC cable

Principal product standard for the complete 600V cable

UL 83 Type THHN

Thermoplastic-insulated conductor

PVC insulation plus clear nylon conductor jacket

UL 66 Type TFFN

Flexible-fixture wire reference

Additional conductor reference listed by the brochure

ANSI/ICEA S-73-532

Control-cable construction / identification

Method 1, Table E-2 core color coding

UL 1581 / UL 1685

Cable tests / flame exposure

Test references listed by the brochure

ASTM / RoHS

Materials and substance compliance

Applicable ASTM standards and RoHS are stated in the brochure

The standards listed by the brochure play different roles. UL 1277 addresses the completed Type TC cable, while UL 83, UL 66, UL 1581, UL 1685 and ICEA/ASTM references support conductor construction, identification and test requirements. Final markings and approvals should be confirmed on the offered cable documentation.

CABLE CONSTRUCTION

Conductor

Annealed Class B copper, unilay compressed stranded

Conductor Range

16–10 AWG; 26 strands at 16 AWG, 7 strands at 14/12/10 AWG

Insulation

Tough, heat- and moisture-resistant PVC

Conductor Jacket

Clear nylon (polyamide)

Assembly

Non-hygroscopic polyethylene fillers as needed; Mylar binder

Metallic Shield / Drain Wire

None / None

Overall Jacket

Heat-, moisture- and sunlight-resistant black PVC

Core Identification

ICEA S-73-532, Method 1, Table E-2

WHY 16 AWG USES 26 STRANDS

The brochure lists 16 AWG conductors as 26-strand Class B compressed copper, while 14, 12 and 10 AWG conductors use 7 strands. This strand-count distinction is part of the supplied construction schedule and should be retained when preparing manufacturing data or approval documents.

PRODUCT APPLICATIONS

  • Utility-substation control circuits.
  • Indoor or outdoor cable-tray installations.
  • Conduit and underground-duct installations.
  • Direct-burial installations as stated in the brochure.
  • Wet locations up to 75°C conductor operating temperature.
  • Dry locations up to 90°C conductor operating temperature.
  • Locations requiring a heat-, moisture- and sunlight-resistant black PVC overall jacket.

TECHNICAL SPECIFICATIONS

The following values are reproduced from the supplied UL1277 CU THHN CONTROL CABLE brochure. Units are retained in both imperial and metric form as provided in the source.

Conductors AWG Jacket in OD in OD mm Weight lb/1000 ft Weight kg/km
2 16 0.045 0.288 7.3 43 64
3 16 0.045 0.303 7.7 53 79
4 16 0.045 0.329 8.4 66 98
5 16 0.045 0.357 9.1 81 120
7 16 0.045 0.386 9.8 103 153
9 16 0.045 0.447 11.4 134 199
12 16 0.045 0.501 12.7 165 245
2 14 0.045 0.305 7.8 56 83
3 14 0.045 0.322 8.2 74 110
4 14 0.045 0.350 8.9 93 139
5 14 0.045 0.381 9.7 109 162
6 14 0.045 0.413 10.5 129 192
7 14 0.045 0.413 10.5 145 215
8 14 0.045 0.446 11.3 164 243
9 14 0.045 0.478 12.2 182 271
10 14 0.060 0.550 14.0 217 322
12 14 0.060 0.568 14.4 251 373
2 12 0.045 0.340 8.6 75 112
3 12 0.045 0.360 9.2 105 156
4 12 0.045 0.392 10.1 128 190
5 12 0.045 0.428 10.9 154 229
6 12 0.045 0.466 11.8 183 272
7 12 0.045 0.466 11.8 207 308
8 12 0.045 0.504 12.8 234 349
9 12 0.060 0.572 14.5 277 412
10 12 0.060 0.621 15.8 307 457
12 12 0.060 0.641 16.3 358 532
2 10 0.045 0.407 10.3 111 166
3 10 0.045 0.433 11.0 155 230
4 10 0.045 0.473 12.0 198 294
5 10 0.060 0.549 13.9 250 371
6 10 0.060 0.596 15.1 294 437
7 10 0.060 0.596 15.1 333 495
8 10 0.060 0.645 16.4 377 561
9 10 0.060 0.693 17.6 421 626
10 10 0.060 0.755 19.2 467 694
12 10 0.060 0.780 19.8 547 814

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Annealed Class B copper conductors are PVC-insulated, covered with clear nylon, color identified, cabled with polyethylene fillers where needed, wrapped with a Mylar binder and finished with a black PVC overall jacket.

Cable and conductor quality inspection and testing

Inspection

Inspection should verify conductor strand count and size, insulation and nylon layers, core identification, assembly, jacket integrity, finished diameter, cable weight and the electrical and flame-test requirements applicable to the approved construction.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on suitable reels or drums according to cable size, weight and ordered length. Product identification may include UL 1277 / Type TC designation, conductor size and count, voltage, length and project reference, subject to the approved marking.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable identification, packing and requested technical documents are checked against the order. Certification, test reports and project-specific approval records should be agreed before production.

Frequently Asked Questions

What is the principal product standard for this cable?

UL 1277 is the principal standard for the completed 600V Type TC cable. UL 83 Type THHN and UL 66 Type TFFN are additional conductor/component references listed in the brochure.

Yes. The brochure states indoor and outdoor installation in cable trays, conduit and underground duct. Installation details such as fill, support, pulling tension and termination space still need project verification.

The brochure states direct-burial and wet-location use, with conductor operation not exceeding 75°C when wet. Confirm the exact cable marking and approval documentation for the offered construction before procurement.

The supplied product data states a maximum conductor operating temperature of 75°C in wet locations and 90°C in dry locations.

No. Every schedule group is identified as unshielded, and the detailed construction does not include a metallic shield or drain wire. If circuit interference control requires shielding, a separate shielded construction should be selected.

We provide a wide range of cable materials and electrical products, including aluminum conductors, aluminum rods, aluminum wires, overhead conductors, medium and low voltage power cables, cable insulation materials, filling materials, shielding materials, and cable manufacturing consumables.We provide customized solutions according to different cable manufacturing requirements.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!