LiYCY Cable for Screened Signal and Control Wiring

AMPO LiYCY cable combines fine-stranded copper conductors, PVC insulation and an overall tinned copper braid for screened signal and control connections. Choose multicore LiYCY or LiYCY TP twisted pair construction to match your equipment and circuit requirements.

Key Advantages

  • Screened connections: overall tinned copper braid helps reduce electrical interference.
  • Flexible wiring: fine-stranded copper conductors support equipment routing and connection.
  • Two construction options: multicore LiYCY or LiYCY TP twisted pairs to match circuit requirements.

Description

LiYCY cable is a screened PVC cable for measurement, signal and control wiring. Both configurations use fine-stranded bare copper conductors, PVC core insulation, tinned copper braid screening and a grey PVC outer sheath. Multicore LiYCY has cores laid together beneath the screen, while LiYCY TP uses twisted pairs for circuits requiring paired wiring.  Choose by construction, core or pair count and conductor cross-section; dimensions and electrical ratings vary by configuration.

Key Features

  • Overall braid screening: a tinned copper braid surrounds the assembled cores or pairs, helping reduce electrical interference in signal and control connections.

  • Twisted pair option: LiYCY TP arranges conductors in pairs to help reduce coupling between signal circuits. Actual performance also depends on cable routing and installation. 

  • Flexible copper conductors: fine strands of bare copper provide a flexible conductor construction for routing and connection within equipment.

  • Clear core identification: the TP sheet specifies DIN 47100 colour coding; the multicore sheet specifies VDE0250 numbered cores. These identifiers support conductor identification during connection and maintenance. Confirm the selected configuration. 

Product Applications

Typical applications include measurement and weighing equipment, electronic and process control units, machinery signal circuits and low-voltage switchboard signal wiring. The supplied sheets also list office and computer equipment connections. Select the construction and ratings to suit the equipment specification and installation conditions.

Technical Specifications

LiYCY PVC/TCWB/PVC Control Cable — Construction Parameters

Number of CoresNominal Cross-sectional AreaApprox. WeightOverall Diameter
No.mm²kg/kmmm
10.14163.6
20.14203.8
30.14254.0
40.14304.3
50.14364.6
60.14405.0
70.14415.2
80.14445.6
100.14566.3
120.14606.4
140.14656.7
160.14817.2
180.14937.6
210.141038.3
240.141179.0
250.141209.0
270.141249.1
300.141369.4
360.1416010.0
400.1417010.3
440.1418611.1
520.1420011.5
610.1425012.1
10.25173.1
20.25304.5
30.25375.1
40.25445.2
50.25515.7
60.25556.1
70.25606.4
80.25777.1
100.25938.1
120.251048.4
140.251158.7
160.251328.9
180.251379.4
210.2517310.4
240.2518411.4
250.2519011.5
270.2519811.6
300.2521211.9
360.2523812.7
400.2526013.1
440.2529014.3
520.2533314.9
610.2538215.8
20.34335.0
30.34425.4
40.34495.8
50.34596.1
60.34646.6
70.34696.7
80.34847.4
100.341068.5
120.341198.7
140.341329.1
160.341469.6
180.3418810.1
210.3419310.9
240.3421312.0
270.3423212.3
300.3425312.7
360.3429213.6
400.3431814.0
520.3440015.8
610.3445416.6
20.5425.4
30.5515.8
40.5616.5
70.5987.8
120.515610.1
180.521511.8
250.531414.4
20.75566.7
30.75707.1
40.75957.6
50.751308.2
70.751688.9
120.7523212.0
180.7531513.9
250.7541816.5
300.7550018.0
21847.7
311108.5
411309.2
511569.9
7119210.7
12126513.7
18138015.9
25147517.5
34162921.5
21.5978.1
31.51258.9
41.51659.7
51.519310.5
71.524511.3
121.536514.5
181.555316.9
251.572020.1
301.577620.7
421.5114025.5
22.514810.1
32.518810.6
42.523611.6
52.527012.6
72.534013.7
122.558518.5
182.572519.7
3425012.4
4430213.5
5437014.8
7447316.1
3628513.9
4641215.2
5650516.7
41062020.8
51079622.9
416109023.2
516207025.6
425178728.2
525204731.1
435214231.5

LiYCY TP Cable — Construction Parameters

Cable Specification
AWG (Stranding) · mm²
Number of PairsNominal Outer DiameterApprox. Weight
inchesmmlbs/mftkg/km
18 AWG (32/32) · 1.0 mm²20.40610.395142
18 AWG (32/32) · 1.0 mm²30.40910.4116173
18 AWG (32/32) · 1.0 mm²40.44511.3142212
18 AWG (32/32) · 1.0 mm²50.46511.8179266
21 AWG (16/32) · 0.50 mm²20.3398.66293
21 AWG (16/32) · 0.50 mm²30.3438.787129
21 AWG (16/32) · 0.50 mm²40.3709.498146
21 AWG (16/32) · 0.50 mm²60.43711.1133198
21 AWG (16/32) · 0.50 mm²80.51613.1174259
21 AWG (16/32) · 0.50 mm²120.58714.9238354
21 AWG (16/32) · 0.50 mm²160.65016.5308459
24 AWG (14/34) · 0.25 mm²20.2767.03654
24 AWG (14/34) · 0.25 mm²30.2807.14466
24 AWG (14/34) · 0.25 mm²40.2997.65481
24 AWG (14/34) · 0.25 mm²60.3358.577115
24 AWG (14/34) · 0.25 mm²80.40610.387130
24 AWG (14/34) · 0.25 mm²100.43311.0106158
24 AWG (14/34) · 0.25 mm²120.44511.3128190
24 AWG (14/34) · 0.25 mm²160.49212.5160238
24 AWG (14/34) · 0.25 mm²250.63416.1231344
26 AWG (18/38) · 0.14 mm²20.2245.72639
26 AWG (18/38) · 0.14 mm²30.2285.83248
26 AWG (18/38) · 0.14 mm²40.2446.23654
26 AWG (18/38) · 0.14 mm²60.2807.15785
26 AWG (18/38) · 0.14 mm²80.3238.26597
26 AWG (18/38) · 0.14 mm²100.3438.774110
26 AWG (18/38) · 0.14 mm²120.3508.995142
26 AWG (18/38) · 0.14 mm²160.40210.2103154
26 AWG (18/38) · 0.14 mm²200.44511.3124184
26 AWG (18/38) · 0.14 mm²250.49212.5160238
26 AWG (18/38) · 0.14 mm²300.51613.1181270

Product Applications

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Fine-stranded copper conductors are PVC insulated, twisted together, wrapped with polyester tape, screened with tinned copper braid, and finished with a grey PVC sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection should verify conductor construction, insulation and sheath condition, dimensional parameters, electrical characteristics and the applicable catalogue requirements before release.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished control cables are supplied on suitable drums or coils according to cable size, length and shipment requirements. Product identification should distinguish the insulation system, conductor size, number of cores and production batch.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Shipment records should link the supplied cable lengths to the applicable packing list, technical documentation and inspection records to support warehouse handling and project traceability.

Frequently Asked Questions

Which construction should I choose?

Use multicore LiYCY where the circuit requires cores laid together, or LiYCY TP when paired conductors are specified. A two-pair TP cable contains four insulated conductors. Confirm the equipment requirements before replacing an existing cable.

The TP construction has an overall tinned copper braid around the assembled pairs. Individual pair shields are not specified; include this requirement in your enquiry if needed.

Ratings depend on construction and cross-section. Use the table above and request confirmation for multicore sizes above 6 mm². Test voltage is not working voltage.

Outdoor suitability and continuous-motion endurance are not established by the supplied sheets. State UV exposure, moisture and movement requirements before ordering. A flexing bend radius alone does not establish drag-chain suitability.

Provide multicore or TP construction, core or pair count, conductor cross-section, quantity and cut lengths. Include operating voltage, installation conditions, delivery destination and any required test reports or compliance documents.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
liycy-tp-cable
LiYCY Cable for Screened Signal and Control Wiring
BS 6346 PVC Insulated Armoured Cable 6001000 V
BS 5467 XLPE Insulated Armoured Power Cable
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
Compatible Hardware
liycy-tp-cable
LiYCY Cable for Screened Signal and Control Wiring
BS 6346 PVC Insulated Armoured Cable 6001000 V
BS 5467 XLPE Insulated Armoured Power Cable
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
Knowledge Articles
AAC vs AAAC vs ACSR: Which Overhead Conductor to Choose?
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines

For Immediate Assistance, Please Contact us Now!