LiYCY Cable for Screened Signal and Control Wiring
AMPO LiYCY cable combines fine-stranded copper conductors, PVC insulation and an overall tinned copper braid for screened signal and control connections. Choose multicore LiYCY or LiYCY TP twisted pair construction to match your equipment and circuit requirements.
Key Advantages
- Screened connections: overall tinned copper braid helps reduce electrical interference.
- Flexible wiring: fine-stranded copper conductors support equipment routing and connection.
- Two construction options: multicore LiYCY or LiYCY TP twisted pairs to match circuit requirements.
Description
LiYCY cable is a screened PVC cable for measurement, signal and control wiring. Both configurations use fine-stranded bare copper conductors, PVC core insulation, tinned copper braid screening and a grey PVC outer sheath. Multicore LiYCY has cores laid together beneath the screen, while LiYCY TP uses twisted pairs for circuits requiring paired wiring. Choose by construction, core or pair count and conductor cross-section; dimensions and electrical ratings vary by configuration.
Key Features
Overall braid screening: a tinned copper braid surrounds the assembled cores or pairs, helping reduce electrical interference in signal and control connections.
Twisted pair option: LiYCY TP arranges conductors in pairs to help reduce coupling between signal circuits. Actual performance also depends on cable routing and installation.
Flexible copper conductors: fine strands of bare copper provide a flexible conductor construction for routing and connection within equipment.
Clear core identification: the TP sheet specifies DIN 47100 colour coding; the multicore sheet specifies VDE0250 numbered cores. These identifiers support conductor identification during connection and maintenance. Confirm the selected configuration.
Product Applications
Typical applications include measurement and weighing equipment, electronic and process control units, machinery signal circuits and low-voltage switchboard signal wiring. The supplied sheets also list office and computer equipment connections. Select the construction and ratings to suit the equipment specification and installation conditions.
Technical Specifications
LiYCY PVC/TCWB/PVC Control Cable — Construction Parameters
| Number of Cores | Nominal Cross-sectional Area | Approx. Weight | Overall Diameter |
|---|---|---|---|
| No. | mm² | kg/km | mm |
| 1 | 0.14 | 16 | 3.6 |
| 2 | 0.14 | 20 | 3.8 |
| 3 | 0.14 | 25 | 4.0 |
| 4 | 0.14 | 30 | 4.3 |
| 5 | 0.14 | 36 | 4.6 |
| 6 | 0.14 | 40 | 5.0 |
| 7 | 0.14 | 41 | 5.2 |
| 8 | 0.14 | 44 | 5.6 |
| 10 | 0.14 | 56 | 6.3 |
| 12 | 0.14 | 60 | 6.4 |
| 14 | 0.14 | 65 | 6.7 |
| 16 | 0.14 | 81 | 7.2 |
| 18 | 0.14 | 93 | 7.6 |
| 21 | 0.14 | 103 | 8.3 |
| 24 | 0.14 | 117 | 9.0 |
| 25 | 0.14 | 120 | 9.0 |
| 27 | 0.14 | 124 | 9.1 |
| 30 | 0.14 | 136 | 9.4 |
| 36 | 0.14 | 160 | 10.0 |
| 40 | 0.14 | 170 | 10.3 |
| 44 | 0.14 | 186 | 11.1 |
| 52 | 0.14 | 200 | 11.5 |
| 61 | 0.14 | 250 | 12.1 |
| 1 | 0.25 | 17 | 3.1 |
| 2 | 0.25 | 30 | 4.5 |
| 3 | 0.25 | 37 | 5.1 |
| 4 | 0.25 | 44 | 5.2 |
| 5 | 0.25 | 51 | 5.7 |
| 6 | 0.25 | 55 | 6.1 |
| 7 | 0.25 | 60 | 6.4 |
| 8 | 0.25 | 77 | 7.1 |
| 10 | 0.25 | 93 | 8.1 |
| 12 | 0.25 | 104 | 8.4 |
| 14 | 0.25 | 115 | 8.7 |
| 16 | 0.25 | 132 | 8.9 |
| 18 | 0.25 | 137 | 9.4 |
| 21 | 0.25 | 173 | 10.4 |
| 24 | 0.25 | 184 | 11.4 |
| 25 | 0.25 | 190 | 11.5 |
| 27 | 0.25 | 198 | 11.6 |
| 30 | 0.25 | 212 | 11.9 |
| 36 | 0.25 | 238 | 12.7 |
| 40 | 0.25 | 260 | 13.1 |
| 44 | 0.25 | 290 | 14.3 |
| 52 | 0.25 | 333 | 14.9 |
| 61 | 0.25 | 382 | 15.8 |
| 2 | 0.34 | 33 | 5.0 |
| 3 | 0.34 | 42 | 5.4 |
| 4 | 0.34 | 49 | 5.8 |
| 5 | 0.34 | 59 | 6.1 |
| 6 | 0.34 | 64 | 6.6 |
| 7 | 0.34 | 69 | 6.7 |
| 8 | 0.34 | 84 | 7.4 |
| 10 | 0.34 | 106 | 8.5 |
| 12 | 0.34 | 119 | 8.7 |
| 14 | 0.34 | 132 | 9.1 |
| 16 | 0.34 | 146 | 9.6 |
| 18 | 0.34 | 188 | 10.1 |
| 21 | 0.34 | 193 | 10.9 |
| 24 | 0.34 | 213 | 12.0 |
| 27 | 0.34 | 232 | 12.3 |
| 30 | 0.34 | 253 | 12.7 |
| 36 | 0.34 | 292 | 13.6 |
| 40 | 0.34 | 318 | 14.0 |
| 52 | 0.34 | 400 | 15.8 |
| 61 | 0.34 | 454 | 16.6 |
| 2 | 0.5 | 42 | 5.4 |
| 3 | 0.5 | 51 | 5.8 |
| 4 | 0.5 | 61 | 6.5 |
| 7 | 0.5 | 98 | 7.8 |
| 12 | 0.5 | 156 | 10.1 |
| 18 | 0.5 | 215 | 11.8 |
| 25 | 0.5 | 314 | 14.4 |
| 2 | 0.75 | 56 | 6.7 |
| 3 | 0.75 | 70 | 7.1 |
| 4 | 0.75 | 95 | 7.6 |
| 5 | 0.75 | 130 | 8.2 |
| 7 | 0.75 | 168 | 8.9 |
| 12 | 0.75 | 232 | 12.0 |
| 18 | 0.75 | 315 | 13.9 |
| 25 | 0.75 | 418 | 16.5 |
| 30 | 0.75 | 500 | 18.0 |
| 2 | 1 | 84 | 7.7 |
| 3 | 1 | 110 | 8.5 |
| 4 | 1 | 130 | 9.2 |
| 5 | 1 | 156 | 9.9 |
| 7 | 1 | 192 | 10.7 |
| 12 | 1 | 265 | 13.7 |
| 18 | 1 | 380 | 15.9 |
| 25 | 1 | 475 | 17.5 |
| 34 | 1 | 629 | 21.5 |
| 2 | 1.5 | 97 | 8.1 |
| 3 | 1.5 | 125 | 8.9 |
| 4 | 1.5 | 165 | 9.7 |
| 5 | 1.5 | 193 | 10.5 |
| 7 | 1.5 | 245 | 11.3 |
| 12 | 1.5 | 365 | 14.5 |
| 18 | 1.5 | 553 | 16.9 |
| 25 | 1.5 | 720 | 20.1 |
| 30 | 1.5 | 776 | 20.7 |
| 42 | 1.5 | 1140 | 25.5 |
| 2 | 2.5 | 148 | 10.1 |
| 3 | 2.5 | 188 | 10.6 |
| 4 | 2.5 | 236 | 11.6 |
| 5 | 2.5 | 270 | 12.6 |
| 7 | 2.5 | 340 | 13.7 |
| 12 | 2.5 | 585 | 18.5 |
| 18 | 2.5 | 725 | 19.7 |
| 3 | 4 | 250 | 12.4 |
| 4 | 4 | 302 | 13.5 |
| 5 | 4 | 370 | 14.8 |
| 7 | 4 | 473 | 16.1 |
| 3 | 6 | 285 | 13.9 |
| 4 | 6 | 412 | 15.2 |
| 5 | 6 | 505 | 16.7 |
| 4 | 10 | 620 | 20.8 |
| 5 | 10 | 796 | 22.9 |
| 4 | 16 | 1090 | 23.2 |
| 5 | 16 | 2070 | 25.6 |
| 4 | 25 | 1787 | 28.2 |
| 5 | 25 | 2047 | 31.1 |
| 4 | 35 | 2142 | 31.5 |
LiYCY TP Cable — Construction Parameters
| Cable Specification AWG (Stranding) · mm² | Number of Pairs | Nominal Outer Diameter | Approx. Weight | ||
|---|---|---|---|---|---|
| inches | mm | lbs/mft | kg/km | ||
| 18 AWG (32/32) · 1.0 mm² | 2 | 0.406 | 10.3 | 95 | 142 |
| 18 AWG (32/32) · 1.0 mm² | 3 | 0.409 | 10.4 | 116 | 173 |
| 18 AWG (32/32) · 1.0 mm² | 4 | 0.445 | 11.3 | 142 | 212 |
| 18 AWG (32/32) · 1.0 mm² | 5 | 0.465 | 11.8 | 179 | 266 |
| 21 AWG (16/32) · 0.50 mm² | 2 | 0.339 | 8.6 | 62 | 93 |
| 21 AWG (16/32) · 0.50 mm² | 3 | 0.343 | 8.7 | 87 | 129 |
| 21 AWG (16/32) · 0.50 mm² | 4 | 0.370 | 9.4 | 98 | 146 |
| 21 AWG (16/32) · 0.50 mm² | 6 | 0.437 | 11.1 | 133 | 198 |
| 21 AWG (16/32) · 0.50 mm² | 8 | 0.516 | 13.1 | 174 | 259 |
| 21 AWG (16/32) · 0.50 mm² | 12 | 0.587 | 14.9 | 238 | 354 |
| 21 AWG (16/32) · 0.50 mm² | 16 | 0.650 | 16.5 | 308 | 459 |
| 24 AWG (14/34) · 0.25 mm² | 2 | 0.276 | 7.0 | 36 | 54 |
| 24 AWG (14/34) · 0.25 mm² | 3 | 0.280 | 7.1 | 44 | 66 |
| 24 AWG (14/34) · 0.25 mm² | 4 | 0.299 | 7.6 | 54 | 81 |
| 24 AWG (14/34) · 0.25 mm² | 6 | 0.335 | 8.5 | 77 | 115 |
| 24 AWG (14/34) · 0.25 mm² | 8 | 0.406 | 10.3 | 87 | 130 |
| 24 AWG (14/34) · 0.25 mm² | 10 | 0.433 | 11.0 | 106 | 158 |
| 24 AWG (14/34) · 0.25 mm² | 12 | 0.445 | 11.3 | 128 | 190 |
| 24 AWG (14/34) · 0.25 mm² | 16 | 0.492 | 12.5 | 160 | 238 |
| 24 AWG (14/34) · 0.25 mm² | 25 | 0.634 | 16.1 | 231 | 344 |
| 26 AWG (18/38) · 0.14 mm² | 2 | 0.224 | 5.7 | 26 | 39 |
| 26 AWG (18/38) · 0.14 mm² | 3 | 0.228 | 5.8 | 32 | 48 |
| 26 AWG (18/38) · 0.14 mm² | 4 | 0.244 | 6.2 | 36 | 54 |
| 26 AWG (18/38) · 0.14 mm² | 6 | 0.280 | 7.1 | 57 | 85 |
| 26 AWG (18/38) · 0.14 mm² | 8 | 0.323 | 8.2 | 65 | 97 |
| 26 AWG (18/38) · 0.14 mm² | 10 | 0.343 | 8.7 | 74 | 110 |
| 26 AWG (18/38) · 0.14 mm² | 12 | 0.350 | 8.9 | 95 | 142 |
| 26 AWG (18/38) · 0.14 mm² | 16 | 0.402 | 10.2 | 103 | 154 |
| 26 AWG (18/38) · 0.14 mm² | 20 | 0.445 | 11.3 | 124 | 184 |
| 26 AWG (18/38) · 0.14 mm² | 25 | 0.492 | 12.5 | 160 | 238 |
| 26 AWG (18/38) · 0.14 mm² | 30 | 0.516 | 13.1 | 181 | 270 |
Product Applications
Request the Complete Data Sheet
From Production to Delivery
From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.
Production
Fine-stranded copper conductors are PVC insulated, twisted together, wrapped with polyester tape, screened with tinned copper braid, and finished with a grey PVC sheath.
Inspection
Inspection should verify conductor construction, insulation and sheath condition, dimensional parameters, electrical characteristics and the applicable catalogue requirements before release.
Packaging
Finished control cables are supplied on suitable drums or coils according to cable size, length and shipment requirements. Product identification should distinguish the insulation system, conductor size, number of cores and production batch.
Shipping
Shipment records should link the supplied cable lengths to the applicable packing list, technical documentation and inspection records to support warehouse handling and project traceability.
Frequently Asked Questions
Which construction should I choose?
Use multicore LiYCY where the circuit requires cores laid together, or LiYCY TP when paired conductors are specified. A two-pair TP cable contains four insulated conductors. Confirm the equipment requirements before replacing an existing cable.
Is each pair individually shielded?
The TP construction has an overall tinned copper braid around the assembled pairs. Individual pair shields are not specified; include this requirement in your enquiry if needed.
What voltage applies to my cable?
Ratings depend on construction and cross-section. Use the table above and request confirmation for multicore sizes above 6 mm². Test voltage is not working voltage.
Can it be used outdoors or in drag chains?
Outdoor suitability and continuous-motion endurance are not established by the supplied sheets. State UV exposure, moisture and movement requirements before ordering. A flexing bend radius alone does not establish drag-chain suitability.
What do I need for a quotation?
Provide multicore or TP construction, core or pair count, conductor cross-section, quantity and cut lengths. Include operating voltage, installation conditions, delivery destination and any required test reports or compliance documents.
Request for Free Consultation
Contact Information
Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.