AS/NZS 3008 Armoured Control Cable 0.6/1kV

AS/NZS 3008 Armoured Control Cable is a 0.6/1kV multicore-plus-earth cable designed for fixed control circuits where conductor size, installation method, current-carrying capacity and voltage drop must be considered together. The cable uses plain annealed copper conductors, PVC V-90 insulation, PVC bedding, galvanised steel wire armour and PVC 5V-90 outer sheath. For the available 1.5 mm² and 2.5 mm² sizes, current ratings are provided for unenclosed-in-air, direct-buried and buried-in-duct installations, together with conductor resistance, reactance and three-phase voltage-drop data to support practical cable selection in commercial, industrial, mining and utility systems.

Product Highlights

  • 6/1kV multicore + earth armoured control cable.
  • 5 mm² and 2.5 mm² plain annealed copper conductor sizes.
  • Current ratings for air, direct-buried and duct installation.
  • DC and AC resistance data for conductor evaluation.
  • Reactance and three-phase voltage-drop values provided.
  • PVC V-90 insulation and PVC 5V-90 outer sheath.
  • Galvanised steel wire armour for mechanical protection.
  • Available from 2C+E to 50C+E.

Cable Construction

Rated Voltage

0.6/1kV

Conductor

Plain annealed copper

1.5 mm² Conductor

7/0.50 mm

2.5 mm² Conductor

7/0.67 mm

Insulation

PVC V-90

Core Identification

White cores with black numbering; green/yellow earth

Bedding

PVC bedding

Armour

Galvanised steel wire armour

Outer Sheath

PVC 5V-90

Sheath Colour

Orange; other colours available on request

Current Rating by Installation Method

The same conductor size can carry different current depending on how the cable is installed because heat dissipation changes with the surrounding environment. The values below therefore separate unenclosed-in-air, direct-buried and buried-in-duct conditions, and also distinguish 2C+E from larger multicore configurations.

Area mm²

Configuration

Air A

Direct Buried A

In Ducts A

Max DC R @20°C Ω/km

Max AC R @75°C Ω/km

Reactance Ω/km

3-ph V-drop @75°C mV/A·m

1.5

2C+E

18

28

22

13.6

16.5

0.111

33.0

1.5

3-50C+E

15

24

19

13.6

16.5

0.111

33.0

2.5

2C+E

26

40

31

7.41

9.01

0.102

18.0

2.5

3-50C+E

22

34

26

7.41

9.01

0.102

18.0

How to Read the Ratings

Installation Method

For 2C+E cables, 1.5 mm² is rated at 18 A in air, 28 A direct buried and 22 A in ducts, while 2.5 mm² is rated at 26 A, 40 A and 31 A respectively. These differences show why installation method must be confirmed before cable size is selected.

Core Count

The available data groups 3C+E through 50C+E separately from 2C+E. At the same conductor area, the grouped multicore rating is lower. For example, 2.5 mm² is 22 A in air for 3-50C+E compared with 26 A for 2C+E.

Resistance and Voltage Drop

The 2.5 mm² conductor has lower resistance and lower voltage-drop data than the 1.5 mm² conductor. Maximum d.c. resistance at 20°C falls from 13.6 Ω/km to 7.41 Ω/km, while the listed three-phase voltage drop at 75°C falls from 33.0 to 18.0 mV/A·m. This makes conductor size, route length and allowable voltage drop important parts of final selection.

Typical Applications

  • Industrial control circuits requiring defined current capacity.
  • Commercial building control systems.
  • Mining installations with mechanical-protection requirements.
  • Utility and electricity-authority control networks.
  • Direct-buried circuits.
  • Underground ducts.
  • Conduit installations.
  • Unenclosed fixed installations where permitted by the project design.

Available Product Range

Area

Conductor

Core Range

Core Insulation

Earth Conductor

Armour Range

Overall Diameter Range

1.5 mm²

7/0.50

2C+E to 50C+E

0.8 mm

1.5 mm²

0.90-1.60 mm

14.5-36.1 mm

2.5 mm²

7/0.67

2C+E to 50C+E

0.8 mm

2.5 mm²

0.90-2.00 mm

15.6-41.7 mm

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Plain annealed copper conductors are insulated with PVC V-90, laid up with the required earth conductor, bedded, armoured with galvanised steel wire and finished with a PVC 5V-90 outer sheath. Production follows the approved core count, conductor size and dimensional schedule.

Cable and conductor quality inspection and testing

Inspection

Inspection includes conductor resistance, insulation and sheath condition, armour integrity, overall dimensions and electrical checks relevant to the approved cable schedule. Current-rating selection is then matched to the intended installation condition.

Packaged cable drums stored in the factory warehouse

Packaging

Finished cable is wound onto suitable drums according to ordered size and length, with ends protected and drum identification prepared for project traceability.

Wooden cable drums secured inside a shipping container

Shipping

Before shipment, cable drums, packing records and technical documents are checked against the order. Test and inspection documentation can be supplied according to customer and project requirements.

Frequently Asked Questions

What is AS/NZS 3008 Armoured Control Cable?

It is a 0.6/1kV multicore-plus-earth armoured control cable presented with installation-based current-rating, resistance, reactance and voltage-drop data for practical cable selection.

18 A in air, 28 A direct buried and 22 A in ducts.

26 A in air, 40 A direct buried and 31 A in ducts.

The listed three-phase voltage drop at 75°C is 18.0 mV/A·m.

The product data treats the larger multicore configurations separately because their thermal conditions differ from 2C+E.

Yes. Direct burial is one of the intended installation conditions for this product range.

Typical Applications

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
BS 7629-1 SR Insulated Fire Resistant Control Cable 300/500V
BS 7629-1 Fire Resistant Screened Control Cable 300/500V
BS 5839-9 Emergency Voice Communication Fire Resistant Screened Cable
Compatible Hardware
BS 7629-1 SR Insulated Fire Resistant Control Cable 300/500V
BS 7629-1 Fire Resistant Screened Control Cable 300/500V
BS 5839-9 Emergency Voice Communication Fire Resistant Screened Cable
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!