UL 1277 THHN/THWN-2 Screened Control Cable 600V

UL 1277 THHN/THWN-2 Screened Control Cable is a 600V, 90°C multiconductor tray-control cable using bare annealed copper conductors, PVC-FR/nylon insulation, an aluminum-tape overall screen, a tinned-copper drain wire and a special PVC outer sheath. It is intended for industrial control routes that may include cable trays, wireways, ducts, conduit, direct burial, wet or dry locations and outdoor tray installation.

PRODUCT OVERVIEW

This screened control cable combines THHN/THWN-2 insulated circuit conductors with an overall aluminum-tape screen and dedicated tinned-copper drain wire. The construction provides a 600V control-cable solution for industrial installations where both tray-cable routing and electrostatic screening are required.

The product data also identifies Class 1, Division 2 hazardous-location applications, including oil, gas and petrochemical environments. Project use in hazardous locations should be coordinated with the applicable electrical code, sealing method, fittings and the specific cable listing required by the installation.

KEY FEATURES

  • UL 1277 referenced complete tray-cable construction.
  • 600V voltage rating and +90°C temperature rating.
  • THHN/THWN-2 style PVC-FR / nylon insulated conductors.
  • Aluminum-tape overall screen with tinned-copper drain wire.
  • Special black PVC outer sheath.
  • Listed for tray, wireway, duct and conduit applications in the source data.
  • Direct-burial, wet/dry and outdoor tray applications stated in the source data.
  • Sunlight-resistant outdoor tray use stated in the source data.
  • Class 1, Division 2 hazardous-location use stated in the source data.

CABLE CONSTRUCTION

Conductor

Bare annealed copper

Insulation

PVC-FR / Nylon (flame-retardant PVC with nylon covering)

Screen

Aluminum tape

Drain Wire

Tinned copper, 16 AWG, 7-strand

Ripcord

Nylon

Outer Sheath

Special PVC

Sheath Colour

Black

Core Identification

Color coded as E2 per ICEA S-73-532

UL 1277 RELATED DESIGN FEATURES

Design Feature

Product Relevance

Multiconductor Cable

2 to 50 cores in the listed product schedule

Tray / Raceway Use

Matches the product’s tray, wireway, duct and conduit applications

Overall Jacket

Special PVC outer sheath protects the screened multicore assembly

Metal Shield

Aluminum-tape overall screen

Drain Wire

Tinned-copper 16 AWG, 7-strand drain wire supports shield termination

Outdoor / Wet-Dry Use

Source data lists wet/dry, direct-burial and sunlight-resistant outdoor tray applications

THHN/THWN-2 Conductors

PVC-FR / nylon insulated conductors referenced to UL 83 as a related standard

STANDARD REFERENCE & COMPLIANCE

Item

Details

Referenced Standard

UL 1277

Current Status

Active

Current Edition

Edition 6

Current Revision

May 29, 2025

Product Rating

600V screened control / tray cable

Compliance Note

For projects requiring a specific UL listing or hazardous-location approval, confirm the applicable cable marking, listing scope, installation method and project documentation before approval.

UL 1277 covers multiconductor electrical power and control tray cables and permits constructions with one or more metal shields. The standard’s installation scope includes cable trays and raceways, with outdoor messenger-supported use addressed by the standard.

WHY UL 1277 IS THE MAIN PRODUCT STANDARD

UL 1277 is the strongest product-level reference in this cable specification because it addresses the complete multiconductor tray-cable assembly rather than only one material or conductor component. For buyers, this means the standard page should focus on the finished cable’s construction, tray/raceway use, overall jacket, screening system and installation environment.

PRODUCT APPLICATIONS

  • Industrial control circuits in cable trays and wireways.
  • Duct and conduit installations.
  • Direct-buried control-cable routes where the specified construction and listing permit.
  • Wet or dry industrial locations.
  • Outdoor cable-tray installations requiring sunlight-resistant cable.
  • Oil, gas and petrochemical facilities where the project calls for Class 1, Division 2 installation and the cable/listing requirements are satisfied.
  • Screened control circuits routed near electrical equipment or power circuits.

The following dimensions and ampacity values are reproduced from the source product data for the listed 600V screened cable constructions.

Cores AWG PVC Insul. mm Nylon mm Sheath mm Overall Dia. mm Weight kg/km Nominal Ampacity A
2 10 0.51 0.10 1.14 10.87 189 40
2 12 0.38 0.10 1.14 9.35 132 30.0
3 10 0.51 0.10 1.14 11.52 251 40
3 12 0.38 0.10 1.14 9.87 174 30.0
3 14 0.38 0.10 1.14 8.67 129 25.0
4 10 0.51 0.10 1.14 12.61 290 32/40
4 12 0.38 0.10 1.14 10.74 219 24.0/30.0
4 14 0.38 0.10 1.14 9.42 159 20.0/25.0
5 10 0.51 0.10 1.52 14.57 414 32
5 12 0.38 0.10 1.14 11.69 272 24.0
5 14 0.38 0.10 1.14 10.24 190 20.0
6 10 0.51 0.10 1.52 15.82 479 32
6 12 0.38 0.10 1.14 12.70 310 24.0
6 14 0.38 0.10 1.14 11.10 220 20.0
7 10 0.51 0.10 1.52 15.82 540 28
7 12 0.38 0.10 1.14 12.70 338 21.0
7 14 0.38 0.10 1.14 11.10 243 17.5
8 10 0.51 0.10 1.52 17.35 609 28
8 12 0.38 0.10 1.52 14.53 394 21.0
8 14 0.38 0.10 1.14 12.14 277 17.5
9 10 0.51 0.10 1.52 18.69 679 28
9 12 0.38 0.10 1.52 15.60 470 21.0
9 14 0.38 0.10 1.52 13.06 307 17.5
10 10 0.51 0.10 1.52 19.95 748 20
10 12 0.38 0.10 1.52 16.61 513 21.0
10 14 0.38 0.10 1.52 14.68 362 12.5
11 10 0.51 0.10 1.52 20.24 811 20
11 12 0.38 0.10 1.52 16.84 549 15.0
11 14 0.38 0.10 1.52 14.68 388 12.5
12 10 0.51 0.10 2.03 21.89 930 20
12 12 0.38 0.10 1.52 17.34 595 15.0
12 14 0.38 0.10 1.52 15.31 421 12.5
13 10 0.51 0.10 2.03 22.27 984 20
13 12 0.38 0.10 1.52 17.64 634 15.0
13 14 0.38 0.10 1.52 15.57 443 12.5
14 10 0.51 0.10 2.03 22.98 1116 20
14 12 0.38 0.10 1.52 18.21 677 15.0
14 14 0.38 0.10 1.52 16.06 473 12.5
15 10 0.51 0.10 2.03 23.56 1173 20
15 12 0.38 0.10 1.52 18.68 717 15.0
15 14 0.38 0.10 1.52 16.46 501 12.5
16 10 0.51 0.10 2.03 24.19 1262 20
16 12 0.38 0.10 1.52 19.19 747 15.0
16 14 0.38 0.10 1.52 16.89 533 12.5
19 10 0.51 0.10 2.03 25.45 1376 20
19 12 0.38 0.10 1.52 20.19 870 15.0
19 14 0.38 0.10 1.52 17.75 615 12.5
20 10 0.51 0.10 2.03 26.21 1443 20
20 12 0.38 0.10 1.52 20.80 933 15.0
20 14 0.38 0.10 1.52 18.27 643 12.5
25 10 0.51 0.10 2.03 29.35 1771 18
25 12 0.38 0.10 2.03 24.33 1176 13.5
25 14 0.38 0.10 1.52 20.42 787 11.3
30 10 0.51 0.10 2.03 31.36 2098 18
30 12 0.38 0.10 2.03 25.94 1379 13.5
30 14 0.38 0.10 2.03 22.82 972 11.3
37 10 0.51 0.10 2.03 33.83 2544 16
37 12 0.38 0.10 2.03 27.91 1665 12.0
37 14 0.38 0.10 2.03 24.51 1174 10.0
40 10 0.51 0.10 2.03 35.13 2738 16
40 12 0.38 0.10 2.03 28.95 1827 12.0
40 14 0.38 0.10 2.03 25.40 1262 10.0
45 10 0.51 0.10 2.03 37.23 3056 14
45 12 0.38 0.10 2.03 30.63 2039 10.5
45 14 0.38 0.10 2.03 26.84 1403 8.8
50 10 0.51 0.10 2.03 38.65 3378 14
50 12 0.38 0.10 2.03 31.77 2245 10.5
50 14 0.38 0.10 2.03 27.81 1537 8.8

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Bare annealed copper conductors are insulated with the PVC-FR / nylon system, assembled into the required multicore construction, screened with aluminum tape together with the tinned-copper drain wire, and protected by the special PVC outer sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, PVC/nylon insulation, core identification, aluminum-tape screen condition, drain-wire continuity, outer-jacket integrity, finished diameter and project-required electrical / flame / listing checks.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on suitable drums according to ordered size, weight and length. Cable ends are protected and drum identification can include the standard reference, conductor size, core count, voltage rating, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable drums and technical documents are checked against the order. Requested inspection records, technical data, certificates and project submittal documents can be prepared for review.

Frequently Asked Questions

When should I specify UL 1277 for this screened control cable?

UL 1277 is the useful reference when the project treats the product as a complete multiconductor tray/control cable rather than simply a group of THHN/THWN-2 conductors. It is especially relevant when the installation uses cable tray, raceway, conduit or other industrial cable-routing systems and the finished cable assembly must be reviewed as one product.

The source product data lists Class 1, Division 2 hazardous-location applications. The final installation still needs to satisfy the applicable electrical code, cable listing, sealing and fitting requirements for the project. For oil, gas or petrochemical work, include the hazardous-area classification in the RFQ so the required documentation can be confirmed before approval.

The aluminum tape forms an overall electrostatic screen around the multicore assembly, while the tinned-copper drain wire provides a practical connection point for terminating that screen. The grounding method should follow the project’s EMC and control-system philosophy rather than being assumed from the cable construction alone.

The source data lists direct burial, wet/dry locations and outdoor cable trays where a sunlight-resistant rating is required. The actual project should still confirm the cable marking, burial method, mechanical protection, fittings and any local code requirements before installation.

Provide the core count, AWG size, total length, installation method, required cable marking and whether direct burial, sunlight resistance or hazardous-location use applies. Also state the required UL documentation, drum length, screen termination requirements and any customer-specific inspection or certification package.

We provide a wide range of cable materials and electrical products, including aluminum conductors, aluminum rods, aluminum wires, overhead conductors, medium and low voltage power cables, cable insulation materials, filling materials, shielding materials, and cable manufacturing consumables.We provide customized solutions according to different cable manufacturing requirements.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!