UL 1277 XHHW/CPE Type TC Control Cable 600V

UL 1277 XHHW/CPE Type TC Control Cable is a compact, flame-retardant 600V multicore control cable built with XHHW-2 copper conductors, FRXLPE insulation and a CPE outer jacket. It is intended for industrial power and control circuits where Type TC tray-cable installation, moisture resistance and outdoor durability are required.

PRODUCT OVERVIEW

The cable combines stranded bare annealed copper conductors with flame-retardant and moisture-resistant FRXLPE insulation and a flame-retardant, moisture- and sunlight-resistant CPE jacket. The listed conductor sizes are AWG 14, 12 and 10, and the product is rated 600V for wet or dry locations at temperatures up to 90°C.

Primary installation environments include cable trays, raceways and outdoor messenger-supported routes. The product is also listed for direct burial, Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions with three or more conductors are identified as suitable for exposed runs (TC-ER) in the supplied product data.

KEY FEATURES

  • UL 1277 Type TC control / tray cable product basis.
  • 600V, 90°C wet-or-dry construction.
  • XHHW-2 stranded bare annealed copper conductors.
  • Flame-retardant, moisture-resistant FRXLPE insulation.
  • Flame-retardant, moisture- and sunlight-resistant CPE jacket.
  • PVC or LSOH jacket options available upon request.
  • Direct burial and Class 1, Division 2 applications stated in the product data.
  • TC-ER exposed-run construction stated for cables with three or more conductors.
  • AWG 14, AWG 12 and AWG 10 parameter schedules.

CABLE CONSTRUCTION

Conductor

Stranded bare annealed copper, 7 strands

Conductor Sizes

AWG 14, AWG 12 and AWG 10

Conductor Type

Type XHHW-2

Insulation

Flame-retardant and moisture-resistant Cross-Linked Polyethylene (FRXLPE)

Outer Jacket

Flame-retardant, moisture- and sunlight-resistant CPE

Optional Jacket Materials

PVC or LSOH available upon request

Jacket Colour

Upon request; black preferred

Voltage Rating

600V

Maximum Listed Temperature

90°C in wet or dry locations

Screen / Armour

None stated in this construction

STANDARD REFERENCE & COMPLIANCE

Item

Details

Referenced Standard

UL 1277 – Electrical Power and Control Tray Cables

Current Status

Active

Current Edition

Edition 6

Current Published Revision

May 29, 2025

Product Designation

Type TC Control Cable, 600V

Compliance Note

For project approval, confirm the required UL listing/marking and specific ratings such as TC-ER, direct burial, wet location, sunlight resistance and hazardous-location use on the offered cable documentation.

UL 1277 TYPE TC DESIGN FOCUS

UL 1277 Focus

How It Applies to This Cable

Complete Cable Assembly

Multicore XHHW-2 conductors under an overall CPE jacket

Cable Tray / Raceway Use

Primary installations include cable trays and raceways

Outdoor Installation

Outdoor routes supported by messenger wire are stated

Direct Burial

Listed as an application in the product data

Wet / Dry Locations

Rated for wet or dry locations up to 90°C

Hazardous Locations

Class 1, Division 2 use is stated; complete installation requirements must also be satisfied

TC-ER

Three or more conductors are stated as listed for exposed runs

TYPE TC VS TC-ER

Type TC identifies the tray-cable product category. TC-ER adds an exposed-run application for qualifying constructions outside the tray under the applicable installation rules. For this product family, the supplied data states that constructions with three or more conductors are listed for exposed runs. Where TC-ER is required, confirm the cable marking and listing for the exact AWG/core construction being ordered.

PRODUCT APPLICATIONS

  • Industrial power and control circuits requiring compact flame-retardant cable.
  • Cable trays and raceways.
  • Outdoor messenger-supported installations.
  • Direct-burial routes where the required cable marking is confirmed.
  • Wet or dry industrial locations up to the listed 90°C rating.
  • Class 1, Division 2 hazardous-location projects as stated in the product data.
  • TC-ER exposed-run applications for qualifying constructions with three or more conductors.

The following schedule reproduces the listed XHHW/CPE Type TC cable dimensions and approximate weights for AWG 14, AWG 12 and AWG 10 constructions.

AWG Cores Jacket in Jacket mm OD in OD mm Weight lb/kft Weight kg/km
14 2 0.045 1.14 0.349 8.86 62 92
14 3 0.045 1.14 0.370 9.40 85 127
14 4 0.045 1.14 0.403 10.24 104 155
14 5 0.045 1.14 0.440 11.18 123 183
14 7 0.045 1.14 0.479 12.17 163 242
14 9 0.060 1.52 0.588 14.94 220 327
14 12 0.060 1.52 0.659 16.74 282 419
14 15 0.060 1.52 0.730 18.54 343 511
14 19 0.060 1.52 0.768 19.51 420 624
14 25 0.080 2.03 0.938 23.83 576 857
14 37 0.080 2.03 1.067 27.10 811 1206
12 2 0.045 1.14 0.384 9.75 84 125
12 3 0.045 1.14 0.408 10.36 114 169
12 4 0.045 1.14 0.445 11.30 145 216
12 5 0.045 1.14 0.487 12.37 170 252
12 7 0.060 1.52 0.562 14.27 241 358
12 9 0.060 1.52 0.651 16.54 303 452
12 12 0.060 1.52 0.732 18.59 392 583
12 15 0.060 1.52 0.813 20.65 480 714
12 19 0.080 2.03 0.896 22.76 622 925
12 25 0.080 2.03 1.043 26.49 804 1196
12 37 0.080 2.03 1.190 30.23 1144 1702
10 2 0.045 1.14 0.431 10.95 114 170
10 3 0.045 1.14 0.459 11.66 159 236
10 4 0.045 1.14 0.502 12.75 204 303
10 5 0.060 1.52 0.581 14.76 257 382
10 7 0.060 1.52 0.632 16.05 342 510
10 9 0.060 1.52 0.736 18.69 433 645
10 12 0.080 2.03 0.870 22.10 593 883
10 15 0.080 2.03 0.964 24.49 726 1081

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

The following schedule reproduces the listed XHHW/CPE Type TC cable dimensions and approximate weights for AWG 14, AWG 12 and AWG 10 constructions.

cable production line with finished cable being wound onto a reel

Production

Stranded bare annealed copper conductors are insulated with FRXLPE, assembled into the required multicore configuration and finished with the specified CPE outer jacket.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, insulation and jacket condition, finished dimensions, cable weight, marking and the project-specific electrical / flame-performance documents required for approval.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cable is wound on suitable reels or drums according to cable size, weight and ordered length. Product identification can include standard reference, AWG size, core count, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, cable identification, packing and requested technical documents are checked against the order. Where fire-performance documentation is required, the applicable test report or certification package should be agreed before production.

Frequently Asked Questions

What products do you supply for the power cable industry?

We provide a wide range of cable materials and electrical products, including aluminum conductors, aluminum rods, aluminum wires, overhead conductors, medium and low voltage power cables, cable insulation materials, filling materials, shielding materials, and cable manufacturing consumables.We provide customized solutions according to different cable manufacturing requirements.

Type TC is the tray-cable product designation, while TC-ER is relevant when qualifying cable is permitted to leave the tray for an exposed run under the applicable installation rules. This product data states that constructions with three or more conductors are listed for exposed runs. For a project, confirm that the exact ordered construction carries the required TC-ER marking.

Yes, those applications are stated for this product family. The CPE jacket is described as moisture- and sunlight-resistant, and the product data also lists direct burial. For formal approval, the actual cable marking/listing should be checked for the required outdoor, wet-location and direct-burial ratings.

The listed CPE jacket is flame retardant and also described as moisture- and sunlight-resistant, which fits the industrial and outdoor installation focus of this Type TC cable. PVC or LSOH can be supplied on request, but a jacket-material change should be reviewed against the project’s flame, environmental and approval requirements.

The product data lists Class 1, Division 2 use. Hazardous-location compliance also depends on the wiring method, fittings, seals, cable marking and applicable electrical code, so the complete installation should be reviewed rather than relying on the cable name alone.

Start with the electrical design, number of control functions and spare-core requirement, then select the required AWG size. After electrical selection, check the finished diameter and weight because these affect tray loading, raceway fill, pulling and termination space.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Compatible Hardware
GD link fitting with central eye and transverse bolted connections for overhead line hardware
Twisted Link Plates — Type GD
LT and EB tower attachment fitting with upper bolted connection and lower eye for insulator strings
Tower Attachment Fittings — Types LT & EB
DIN VDE 0814 LiYCY TP 250V shielded twisted pair signal and control cable
DIN VDE 0814 LiYCY TP Shielded Signal and Control Cable 250V
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!