BS 7629-1 450/750V sR Insulated Fire Resistant Control Cable

BS 7629-1 450/750V sR Insulated Fire Resistant Control Cable is a stranded-copper, silicone-rubber insulated and LSZH sheathed control cable for general power-supply and signal wiring, emergency circuits and fire-circuit control. Available in 2- to 5-core constructions, it is designed around fire-resistant circuit performance while retaining a compact, unscreened multicore construction.

PRODUCT OVERVIEW

The cable is basically designed to BS 7629-1 and uses plain annealed copper conductors stranded to IEC/EN 60228 Class 2. Each conductor is insulated with fire-resistant silicone-rubber compound type EI2, after which the cores are laid together in concentric layers with suitable non-hygroscopic fillers and covered by an LSZH outer sheath.

The design is intended for control and power-supply circuits where fire survival, low-smoke performance and reduced corrosive gas emissions are important. Compared with the screened 450/750V version, this product omits the overall aluminum/polyester screen and drain wire, giving a simpler unscreened construction for circuits that do not require electrostatic-noise screening.

KEY FEATURES

  • Basic design to BS 7629-1.
  • 450/750V rated voltage.
  • Plain annealed copper conductor, stranded IEC/EN 60228 Class 2.
  • Fire-resistant silicone-rubber insulation type EI2.
  • Thermoplastic LSZH outer sheath type LTS3; thermosetting SW2-SW4 can be offered.
  • Unscreened multicore construction.
  • Available in 2-, 3-, 4- and 5-core versions.
  • Available conductor sizes: 1.5 mm², 2.5 mm² and 4.0 mm².
  • Operating temperature: -30°C to +90°C.
  • Installation temperature: -20°C to +50°C.
  • Minimum bending radius: 7.5 × overall diameter.

CABLE CONSTRUCTION

Voltage Rating

450/750V

Conductor

Plain annealed copper, stranded IEC/EN 60228 Class 2

Insulation

Fire-resistant silicone-rubber compound type EI2

Cabling

Cores cabled together in concentric layers with suitable non-hygroscopic fillers

Outer Sheath

Thermoplastic LSZH LTS3; optional thermosetting LSZH SW2-SW4

Sheath Colour

Red; other colours on request

STANDARD BASIS & FIRE PERFORMANCE

BS 7629-1 is the basic design standard identified for this cable. The product also lists a broad fire-performance framework covering circuit integrity, mechanical shock, water spray, flame propagation, halogen content, smoke emission and toxic-gas performance.

Performance

Referenced Test / Standard

Circuit integrity

IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814 (FE180); BS 8434-1 (30 min); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (F3); NF C32-070-2.3 (CR1)

Circuit integrity with mechanical shock

EN 50200 (PH60); CEI 20-36/4-0

Circuit integrity with mechanical shock & water spray

EN 50200 Annex E

System circuit integrity

DIN 4102-12, E30 depending on lay system

Flame retardance – single vertical wire

EN/IEC/BS EN 60332-1-2 and listed equivalents

Reduced fire propagation – bundled cables

EN/IEC/BS EN 60332-3-24 (Cat. C) and listed equivalents

Halogen free

IEC 60754-1 and listed equivalents

No corrosive gas emission

IEC 60754-2 and listed equivalents

Minimum smoke emission

IEC 61034-1&2 and listed equivalents

No toxic gases

NES 02-713; NF C 20-454

PHYSICAL, THERMAL & ELECTRICAL PROPERTIES

Operating Temperature

-30°C to +90°C

Installation Temperature

-20°C to +50°C

Minimum Bending Radius

7.5 × overall diameter

Dielectric Test

2500 V r.m.s. × 5 min (core/core)

Insulation Resistance

≥300 MΩ·km at 20°C

Short-Circuit Temperature

350°C

Conductor Operating Temperature

90°C

Ambient Temperature for Current-Carrying Table

30°C

PRODUCT APPLICATIONS

  • General power-supply control circuits.
  • Signal wiring.
  • Emergency-circuit control.
  • Fire-circuit control.
  • Building-services and industrial control circuits requiring LSZH materials.
  • Fixed multicore installations where overall electrostatic screening is not required.

The listed range covers 2- to 5-core constructions in 1.5 mm², 2.5 mm² and 4.0 mm² conductor sizes. As conductor size and core count increase, the cable overall diameter and approximate mass increase accordingly.

No. of Cores × Cross Section Insulation mm Sheath mm Overall Diameter mm Approx. Weight kg/km
2x1.5 0.8 1.0 7.8 96
2x2.5 0.9 1.1 9.2 138
2x4.0 0.9 1.2 10.5 189
3x1.5 0.8 1.0 8.3 115
3x2.5 0.9 1.1 9.8 169
3x4.0 0.9 1.2 11.6 246
4x1.5 0.8 1.1 9.3 147
4x2.5 0.9 1.2 11.3 222
4x4.0 0.9 1.3 12.5 299
5x1.5 0.8 1.1 10.5 180
5x2.5 0.9 1.2 12.3 259
5x4.0 0.9 1.3 14.0 359

Request the Complete Data Sheet

If you need a specific product catalogue or related standard file, please contact us.

From Production to Delivery

From raw material preparation to final shipmen, every stage is caretuly controled to ensure consistent conductor quality, reliable pertormance,and sae delivery. Our roduction,
inspection, packaging, and logistics processes are managed in accordance with applicable standards and project requirements.

cable production line with finished cable being wound onto a reel

Production

Class 2 stranded copper conductors are insulated with fire-resistant silicone rubber, laid up with suitable non-hygroscopic fillers and finished with the specified LSZH outer sheath.

Cable and conductor quality inspection and testing

Inspection

Inspection focuses on conductor construction, insulation quality, core identification, sheath condition, dielectric test, insulation resistance, overall dimensions and required fire-performance documentation.

Overhead conductors packed on wooden drums for shipment

Packaging

Finished cables are wound onto suitable drums according to ordered size and length. Cable ends are secured and protected, and drum identification can include cable type, voltage, conductor size, core count, length and project reference.

Wooden drums of overhead conductors loaded into shipping container

Shipping

Before shipment, drums and accompanying technical documents are checked against the purchase order and packing list. Test reports, inspection records and product identification can be prepared according to project requirements.

Frequently Asked Questions

What conductor class is used?

IEC/EN 60228 Class 2 stranded copper conductors.

Fire-resistant silicone-rubber compound type EI2.

No. This product is an unscreened multicore fire-resistant control cable.

7.5 times the overall cable diameter.

Request for Free Consultation

Contact Information

Send us your cable requirements and our team will respond quickly with product recommendations, technical support and quotation details.

Explore More

Related Products
BS EN 50266-1:2001 CY LSZH screened flexible control cable with tinned copper wire braid
BS EN 50266-1:2001 CY LSZH Screened Flexible Control Cable 300/500V
BS 7629-1 600/1000V silicone rubber insulated flexible fire resistant control cable
BS 7629-1 600/1000V SR Insulated Flexible Fire Resistant Control Cable
BS 7629-1 450/750V silicone rubber insulated fire resistant control cable
BS 7629-1 450/750V sR Insulated Fire Resistant Control Cable
Compatible Hardware
BS EN 50266-1:2001 CY LSZH screened flexible control cable with tinned copper wire braid
BS EN 50266-1:2001 CY LSZH Screened Flexible Control Cable 300/500V
BS 7629-1 600/1000V silicone rubber insulated flexible fire resistant control cable
BS 7629-1 600/1000V SR Insulated Flexible Fire Resistant Control Cable
BS 7629-1 450/750V silicone rubber insulated fire resistant control cable
BS 7629-1 450/750V sR Insulated Fire Resistant Control Cable
Knowledge Articles
Customer Visits Our Factory for Product Inspection and Quality Verification
AAAC all aluminium alloy conductor stranded wire
AAAC Conductor Selection Guide: How to Choose the Right AAAC for Overhead Lines
International Airport Expansion Project in Saudi Arabia

For Immediate Assistance, Please Contact us Now!